XL-3200T6 AC Electric Energy Meter Dynamic Performance Testing Device
XL-3200T6 Dynamic/Harmonic Electric Energy Meter Calibration Device Series, harmonic measurement range 2~50 times, accuracy level 0.05, harmonic accuracy 0.2 level, can be used for dynamic performance testing and calibration of harmonic electric energy meters and AC electric energy meters.
Product Description
Product Introduction
XL-3200T6 AC Energy Meter Dynamic Performance Testing Device Can output three-phase AC/DC voltage and three-phase AC/DC current, with voltage and current outputs including DC, square wave, triangle wave, sine wave, superimposed harmonics, fundamental wave with low-frequency oscillation, custom waveforms, and various waveform splicing outputs. The -3dB bandwidth can reach 20kHz. Suitable for scenarios requiring complex power waveform signal output, such as dynamic performance testing of energy meters, transformer testing, harmonic analysis, etc.
Features
- High Measurement Accuracy: Power and energy measurement accuracy class 0.05, voltage and current measurement accuracy class 0.05, suitable for measurement and calibration of AC quantities, harmonics, and dynamic performance.
- Standard Meter Method: Built-in 0.05/0.2 class AC/harmonic standard meter; the device uses the standard meter method to verify the tested meter, facilitating traceability and inspection.
- Wide Output and Measurement Range: Output and measurement range 30~420V, 50mA~120A, meeting the verification and calibration requirements of AC energy meters, harmonic energy meters, and AC meters dynamic performance.
- Comprehensive Harmonic Verification Items, including some type tests (XL3203T6): Basic error, pure fundamental wave or each harmonic or fundamental wave superimposed harmonic energy error, start-up, creeping, daily timing error tests, electrical parameters, constant tests, and other harmonic performance testing functions.
- Comprehensive Dynamic Performance Verification Items, including some type tests (XL3200T6): Steady-state basic error, dynamic basic error, dynamic start-up, start-up, creeping, daily timing error tests, electrical parameters, constant tests, and other dynamic performance testing functions.
- No Wiring Meter Testing: Uses the voltage meter fixture required by the State Grid technical specifications, making meter hanging and removal convenient without additional wiring.
- High Output Stability: Uses linear power amplifier, typical output stability can reach 0.005% RG/min.
- 2~50 Harmonic Measurement: Harmonic measurement accuracy 0.2%, meeting current JJG 1106-2015, AC dynamic performance, and IR46 test requirements.
- High Accuracy Second Pulse: Built-in optional high-accuracy GPS clock, typical clock accuracy is 60ns/s, facilitating clock traceability.
- Multi-Position Testing, High Efficiency: Supports 6 meter positions simultaneously, meeting the needs of large batch testing of meters, ensuring efficient verification.
- High Annual Stability: Uses high-precision imported components, typical annual measurement stability is 100 PPM/year, can be used for many years without calibration.
- Professional Software: Supports automatic or semi-automatic verification of DC energy meters, supports verification data recording and management, and can automatically generate verification certificates according to templates after verification, with freely editable templates.
- Human-Machine Interaction, Simple and Flexible: Internal communication uses serial port servers and switches to interconnect all modules via network; control software controls the entire device through network communication.
Technical Parameters
Item | XL-3200T6 | XL-3223T6 |
Accuracy Class | Power/Energy: 0.1/0.05 class, AC/DC: 0.1/0.05 class, Harmonics: 0.5/0.2% | |
Test Phase, Meter Positions | Three-phase, 6 meter positions | |
Voltage Output | Output Range: 30-456V, Stability: 0.05%/min, Output Power: 15VA per meter position | |
Current Output | Output Range: 0.05-120A, Stability: 0.05%/min | |
Frequency Output | Voltage: 0.001-5KHz, Current: 0.001-2.5KHz | Voltage/Current: 0.001-2.5KHz |
Voltage Measurement | Measurement Range: 30-456V | |
Accuracy: 0.1/0.05% RD (30V~420V), 0.1/0.05% RG (0V~420V) | ||
Current Measurement | Measurement Range: 50mA -120A | |
0.1/0.05% RD (0.05A~100A), 0.1/0.05% RG (0A~100A) | ||
Power and Energy Measurement | Range: Combination of voltage and current measurement ranges | |
Accuracy: Active: 0.1/0.05% RD PF≥0.5 (0.05A~100A /30V~420V) | ||
Reactive: 0.2/0.1% RD PF≥0.5 (0.05A~100A /30V~420V) | ||
Harmonic Energy Accuracy: 0.5/0.2% | ||
Harmonic Measurement | Range: 2~50 harmonics, Accuracy: 0.2/0.1% | |
Phase Measurement | Range: 0~359.99 degrees, Accuracy: 0.01/0.05° (Current ≥ 200mA, Voltage ≥ 30V) | |
Frequency Measurement | Range: 45Hz~65Hz, Accuracy: 0.005Hz | |
Power Factor Measurement | Range: -1~0~+1, Accuracy: 0.001/0.0005 | |
Energy Pulse | Pulse Output: Frequency < 10KHz, TTL Level (5V), Load Capacity ≤ 5mA | |
Pulse Input: Pulse Frequency < 1KHz, TTL Level (5V), Load Capacity < 1mA | ||
Annual Stability | Class 0.1: Voltage, Current: ±200PPM/year | |
Class 0.05: Voltage, Current: ±100PPM/year |