Solution Details


Charging pile testing solutions targeting European, American, and Japanese standards

For the testing of European, American, and Japanese standards, domestic methods basically adopt a design based on existing national standard testing equipment, assuming the use of externally purchased national standard to European standard protocol conversion boards, as shown in the figure below:

 

The advantage of this approach is low technical complexity and fast development speed. However, the disadvantage is also fatal, as detailed below:

1. It is impossible to strictly carry out protocol consistency testing for ISO15118-4 and -5, only a few protocol consistency analogy tests can be conducted based on national standard content as a workaround.

2. Compatibility issues: when communication compatibility problems occur causing testing failure, integrators cannot resolve them and must rely on module suppliers.

Our company, through independently developed European, American, and Japanese standard simulators, achieves high flexibility in development and can complete over 600 protocol consistency tests, a capability unmatched by peers, fully comparable to the related equipment of the world-renowned supplier Vector.

Through the above technological development, combined with our existing portable equipment and laboratory equipment platform technology for national standards, we have realized comprehensive testing equipment related to European, American, and Japanese standards, including on-site characteristic testers for European, American, and Japanese standards, laboratory testing platforms, and aging testing platforms.

 

Model

Product Name

Product Image

Main Functions

Grade

Relevant Standards

Selection Notes

XL-942ES

European Standard DC Charging Pile On-site Characteristic Tester

For European standard DC charging pile metrological verification, interoperability testing, protocol consistency testing (exclusive to ES), and performance function testing (ES functions more complete)

Class 0.05

IEC61851-1, IEC61851-23, IEC61851-24,
ISO15118-1, ISO15118-2, ISO15118-3,
ISO15118-4, ISO15118-5, DIN70121,
DIN70122

Comprehensive functions, truly a European standard testing device

XL-942AS

American Standard DC Charging Pile On-site Characteristic Tester

For American standard DC charging pile metrological verification, interoperability testing, protocol consistency testing (exclusive to ES), and performance function testing (ES functions more complete)

Class 0.05

SAEJ1772, IEC61851-1, IEC61851-23,
IEC61851-24, ISO15118-1, ISO15118-2,
ISO15118-3, ISO15118-4, ISO15118-5, DIN70121, DIN70122

Comprehensive functions, truly an American standard testing device

 

 

The related testing items for European, American, and Japanese standards are as follows:

Table 1. DC European and American Standard Testing Items

Project Set

Serial Number

Project

Reference

Interoperability

1

Charging Connection Ready

IEC61851-1

2

Self-check Phase

IEC61851-23

3

Charging Ready Test (including pre-charge)

IEC61851-23

4

Charging Phase

IEC61851-23

5

Normal Charging End

IEC61851-23

6

Charging Connection Control Timing

IEC61851-23

7

Protective Conductor Continuity Check (PE Disconnection)

IEC61851-23

8

Control Pilot Interruption Test

IEC61851-23

9

Pre-charging Insulation Test

IEC61851-23

10

Battery Overvoltage Protection Test

IEC61851-23

11

Emergency Stop Test

IEC61851-23

12

Output Current Error Test

IEC61851-23

13

Output Voltage Error Test

IEC61851-23

14

Charging Current Control Delay Test

IEC61851-23

15

Charging Current Decline Rate Test

IEC61851-23

16

Load Sudden Drop Test

IEC61851-23

17

Charging Pile Voltage Measurement Error

IEC61851-23

18

Charging Pile Current Measurement Error

IEC61851-23

Comprehensive Testing Items

1

Connection Correctness Test

IEC61851-23

2

Power Supply Function

IEC61851-23

3

Power Cut-off Function

IEC61851-23

4

Maximum Allowable Current

IEC61851-23

5

DC Charging Test

IEC61851-23

6

Current Regulation Error

IEC61851-23

7

Current Ripple

IEC61851-23

8

Voltage Regulation Error Measurement

IEC61851-23

9

Current Adjustment Time

IEC61851-23

10

Current Decline Rate

IEC61851-23

11

Voltage Ripple Measurement

IEC61851-23

12

Voltage Measurement Error

IEC61851-23

13

Current Measurement Error

IEC61851-23

14

Compatibility Testing

IEC61851-23

15

Pre-charge Insulation Fault Test

IEC61851-23

16

Output Overvoltage Emergency Stop Test

IEC61851-23

17

Output Overvoltage Error Stop Test

IEC61851-23

18

Message Mode Overvoltage Test

IEC61851-23

19

Short-term Overvoltage Test

IEC61851-23

20

Charging Insulation Fault Test

IEC61851-23

21

Overcurrent Protection Test

IEC61851-23

22

Active Termination Test

IEC61851-23

23

Passive Termination Test

IEC61851-23

24

Error Termination Test

IEC61851-23

25

Emergency Termination Test

IEC61851-23

26

Normal Start

IEC61851-23

27

Charging Pile Wake-up Function Test

IEC61851-23

28

Rated Output Test

IEC61851-23

29

Load Sudden Drop Test

IEC61851-23

30

Input Current Overshoot Test

IEC61851-23

31

CP Grounding Protection Test

IEC61851-23

32

Voltage Detection Test During Adhesion Detection Process

IEC61851-23

33

Insulation Abnormality Test

IEC61851-23

34

Connection Correctness Test

IEC61851-1

35

Continuity of Grounding Conductor

IEC61851-1

36

Power Supply Function

IEC61851-1

37

Power Cut-off Function

IEC61851-1

38

Maximum Allowable Current

IEC61851-1

Other Inspection Items

39

Efficiency Test

NB/T33008.1

40

Power Factor Test

NB/T33008.1

 

  Table 2. ISO15118 Protocol Conformance Test

Serial Number

Project Name

1

TC_SECC_CMN_VTB_V2GTPSessionSetup_001

2

TC_SECC_CMN_VTB_V2GTPSessionSetup_002

3

TC_SECC_CMN_VTB_V2GTPSessionSetup_003

4

TC_SECC_CMN_VTB_V2GTPSessionSetup_004

5

TC_SECC_CMN_VTB_V2GTPSessionSetup_005

6

TC_SECC_CMN_VTB_V2GTPSDP_001

7

TC_SECC_CMN_VTB_V2GTPSDP_002

8

TC_SECC_CMN_VTB_V2GTPSDP_003

9

TC_SECC_CMN_VTB_V2GTPSDP_004

10

TC_SECC_CMN_VTB_V2GTPSDP_005

11

TC_SECC_CMN_VTB_SDP_001

12

TC_SECC_CMN_VTB_SDP_002

13

TC_SECC_CMN_VTB_SDP_003

14

TC_SECC_CMN_VTB_SDP_004

15

TC_SECC_CMN_VTB_SDP_005

16

TC_SECC_CMN_VTB_SDP_006

17

TC_SECC_CMN_VTB_SDP_007

18

TC_SECC_CMN_VTB_SupportedAppProtocol_001

19

TC_SECC_CMN_VTB_SupportedAppProtocol_002

20

TC_SECC_CMN_VTB_SupportedAppProtocol_003

21

TC_SECC_CMN_VTB_SupportedAppProtocol_004

22

TC_SECC_CMN_VTB_SupportedAppProtocol_005

23

TC_SECC_CMN_VTB_SupportedAppProtocol_006

24

TC_SECC_CMN_VTB_SessionSetup_001

25

TC_SECC_CMN_VTB_SessionSetup_002

26

TC_SECC_CMN_VTB_SessionSetup_003

27

TC_SECC_CMN_VTB_SessionSetup_004

28

TC_SECC_DC_VTB_SessionSetup_001

29

TC_SECC_DC_VTB_SessionSetup_002

30

TC_SECC_DC_VTB_SessionSetup_003

31

TC_SECC_DC_VTB_SessionSetup_004

32

TC_SECC_DC_VTB_SessionSetup_005

33

TC_SECC_DC_VTB_SessionSetup_006

34

TC_SECC_CMN_VTB_ServiceDiscovery_001

35

TC_SECC_CMN_VTB_ServiceDiscovery_002

36

TC_SECC_CMN_VTB_ServiceDiscovery_003

37

TC_SECC_CMN_VTB_ServiceDiscovery_004

38

TC_SECC_DC_VTB_ServiceDiscovery_001

39

TC_SECC_DC_VTB_ServiceDiscovery_002

40

TC_SECC_CMN_VTB_PaymentServiceSelection_001

41

TC_SECC_CMN_VTB_PaymentServiceSelection_004

42

TC_SECC_CMN_VTB_PaymentServiceSelection_005

43

TC_SECC_CMN_VTB_PaymentServiceSelection_006

44

TC_SECC_CMN_VTB_PaymentServiceSelection_007

45

TC_SECC_CMN_VTB_PaymentServiceSelection_008

46

TC_SECC_CMN_VTB_PaymentServiceSelection_009

47

TC_SECC_CMN_VTB_PaymentServiceSelection_010

48

TC_SECC_CMN_VTB_PaymentDetails_001

49

TC_SECC_CMN_VTB_PaymentDetails_002

50

TC_SECC_CMN_VTB_PaymentDetails_003

51

TC_SECC_CMN_VTB_PaymentDetails_004

52

TC_SECC_CMN_VTB_PaymentDetails_005

53

TC_SECC_CMN_VTB_PaymentDetails_006

54

TC_SECC_CMN_VTB_PaymentDetails_007

55

TC_SECC_CMN_VTB_PaymentDetails_008

56

TC_SECC_CMN_VTB_PaymentDetails_009

57

TC_SECC_CMN_VTB_PaymentDetails_010

58

TC_SECC_CMN_VTB_Authorization_001

59

TC_SECC_CMN_VTB_Authorization_002

60

TC_SECC_CMN_VTB_Authorization_003

61

TC_SECC_CMN_VTB_Authorization_004

62

TC_SECC_CMN_VTB_Authorization_005

63

TC_SECC_CMN_VTB_Authorization_006

64

TC_SECC_CMN_VTB_Authorization_007

65

TC_SECC_CMN_VTB_Authorization_008

66

TC_SECC_CMN_VTB_Authorization_009

67

TC_SECC_CMN_VTB_Authorization_010

68

TC_SECC_CMN_VTB_Authorization_011

69

TC_SECC_CMN_VTB_Authorization_012

70

TC_SECC_CMN_VTB_Authorization_013

71

TC_SECC_CMN_VTB_Authorization_014

72

TC_SECC_CMN_VTB_Authorization_015

73

TC_SECC_CMN_VTB_Authorization_016

74

TC_SECC_CMN_VTB_Authorization_017

75

TC_SECC_CMN_VTB_ChargeParameterDiscovery_001

76

TC_SECC_CMN_VTB_ChargeParameterDiscovery_002

77

TC_SECC_DC_VTB_ChargeParameterDiscovery_001

78

TC_SECC_DC_VTB_ChargeParameterDiscovery_002

79

TC_SECC_DC_VTB_ChargeParameterDiscovery_003

80

TC_SECC_DC_VTB_ChargeParameterDiscovery_004

81

TC_SECC_DC_VTB_ChargeParameterDiscovery_005

82

TC_SECC_DC_VTB_ChargeParameterDiscovery_006

83

TC_SECC_DC_VTB_ChargeParameterDiscovery_007

84

TC_SECC_DC_VTB_ChargeParameterDiscovery_008

85

TC_SECC_DC_VTB_ChargeParameterDiscovery_009

86

TC_SECC_DC_VTB_ChargeParameterDiscovery_010

87

TC_SECC_DC_VTB_ChargeParameterDiscovery_011

88

TC_SECC_DC_VTB_ChargeParameterDiscovery_012

89

TC_SECC_DC_VTB_ChargeParameterDiscovery_013

90

TC_SECC_DC_VTB_ChargeParameterDiscovery_014

91

TC_SECC_DC_VTB_ChargeParameterDiscovery_015

92

TC_SECC_DC_VTB_ChargeParameterDiscovery_016

93

TC_SECC_DC_VTB_ChargeParameterDiscovery_017

94

TC_SECC_DC_VTB_ChargeParameterDiscovery_018

95

TC_SECC_DC_VTB_ChargeParameterDiscovery_019

96

TC_SECC_DC_VTB_ChargeParameterDiscovery_020

97

TC_SECC_DC_VTB_ChargeParameterDiscovery_021

98

TC_SECC_DC_VTB_ChargeParameterDiscovery_022

99

TC_SECC_DC_VTB_ChargeParameterDiscovery_023

100

TC_SECC_DC_VTB_ChargeParameterDiscovery_024

101

TC_SECC_DC_VTB_ChargeParameterDiscovery_025

102

TC_SECC_DC_VTB_ChargeParameterDiscovery_026

103

TC_SECC_DC_VTB_ChargeParameterDiscovery_027

104

TC_SECC_DC_VTB_ChargeParameterDiscovery_028

105

TC_SECC_DC_VTB_ChargeParameterDiscovery_029

106

TC_SECC_DC_VTB_ChargeParameterDiscovery_030

107

TC_SECC_DC_VTB_ChargeParameterDiscovery_031

108

TC_SECC_DC_VTB_ChargeParameterDiscovery_032

109

TC_SECC_DC_VTB_ChargeParameterDiscovery_033

110

TC_SECC_DC_VTB_ChargeParameterDiscovery_034

111

TC_SECC_DC_VTB_ChargeParameterDiscovery_035

112

TC_SECC_DC_VTB_ChargeParameterDiscovery_036

113

TC_SECC_DC_VTB_PowerDelivery_001

114

TC_SECC_DC_VTB_PowerDelivery_002

115

TC_SECC_DC_VTB_PowerDelivery_003

116

TC_SECC_DC_VTB_PowerDelivery_004

117

TC_SECC_DC_VTB_PowerDelivery_005

118

TC_SECC_DC_VTB_PowerDelivery_006

119

TC_SECC_DC_VTB_PowerDelivery_007

120

TC_SECC_DC_VTB_PowerDelivery_008

121

TC_SECC_DC_VTB_PowerDelivery_009

122

TC_SECC_DC_VTB_PowerDelivery_010

123

TC_SECC_DC_VTB_PowerDelivery_011

124

TC_SECC_DC_VTB_PowerDelivery_012

125

TC_SECC_DC_VTB_PowerDelivery_013

126

TC_SECC_DC_VTB_PowerDelivery_014

127

TC_SECC_DC_VTB_PowerDelivery_015

128

TC_SECC_DC_VTB_PowerDelivery_016

129

TC_SECC_DC_VTB_PowerDelivery_017

130

TC_SECC_DC_VTB_PowerDelivery_018

131

TC_SECC_DC_VTB_PowerDelivery_019

132

TC_SECC_DC_VTB_PowerDelivery_020

133

TC_SECC_DC_VTB_PowerDelivery_021

134

TC_SECC_DC_VTB_SessionStop_001

135

TC_SECC_DC_VTB_SessionStop_002

136

TC_SECC_DC_VTB_SessionStop_003

137

TC_SECC_DC_VTB_SessionStop_004

138

TC_SECC_DC_VTB_SessionStop_005

139

TC_SECC_DC_VTB_SessionStop_006

140

TC_SECC_DC_VTB_SessionStop_007

141

TC_SECC_DC_VTB_SessionStop_008

142

TC_SECC_DC_VTB_SessionStop_009

143

TC_SECC_DC_VTB_CableCheck_001

144

TC_SECC_DC_VTB_CableCheck_002

145

TC_SECC_DC_VTB_CableCheck_003

146

TC_SECC_DC_VTB_CableCheck_004

147

TC_SECC_DC_VTB_CableCheck_005

148

TC_SECC_DC_VTB_CableCheck_006

149

TC_SECC_DC_VTB_CableCheck_007

150

TC_SECC_DC_VTB_CableCheck_008

151

TC_SECC_DC_VTB_PreCharge_001

152

TC_SECC_DC_VTB_PreCharge_002

153

TC_SECC_DC_VTB_PreCharge_003

154

TC_SECC_DC_VTB_PreCharge_004

155

TC_SECC_DC_VTB_CurrentDemand_001

156

TC_SECC_DC_VTB_CurrentDemand_002

157

TC_SECC_DC_VTB_CurrentDemand_003

158

TC_SECC_DC_VTB_CurrentDemand_004

159

TC_SECC_DC_VTB_CurrentDemand_005

160

TC_SECC_DC_VTB_CurrentDemand_006

161

TC_SECC_DC_VTB_CurrentDemand_007

162

TC_SECC_DC_VTB_CurrentDemand_008

163

TC_SECC_DC_VTB_CurrentDemand_009

164

TC_SECC_DC_VTB_WeldingDetection_001

165

TC_SECC_DC_VTB_WeldingDetection_002

166

TC_SECC_DC_VTB_WeldingDetection_003

167

TC_SECC_DC_VTB_WeldingDetection_004

168

TC_SECC_DC_VTB_WeldingDetection_005

169

TC_SECC_CMN_VTB_CmSlacParm_001

170

TC_SECC_CMN_VTB_CmSlacParm_002

171

TC_SECC_CMN_VTB_CmSlacParm_003

172

TC_SECC_CMN_VTB_CmSlacParm_004

173

TC_SECC_CMN_VTB_CmSlacParm_005

174

TC_SECC_CMN_VTB_CmSlacParm_006

175

TC_SECC_CMN_VTB_CmSlacParm_007

176

TC_SECC_CMN_VTB_CmSlacParm_008

177

TC_SECC_CMN_VTB_CmSlacParm_009

178

TC_SECC_CMN_VTB_AttenuationCharacterization_001

179

TC_SECC_CMN_VTB_AttenuationCharacterization_002

180

TC_SECC_CMN_VTB_AttenuationCharacterization_003

181

TC_SECC_CMN_VTB_AttenuationCharacterization_004

182

TC_SECC_CMN_VTB_AttenuationCharacterization_005

183

TC_SECC_CMN_VTB_AttenuationCharacterization_006

184

TC_SECC_CMN_VTB_AttenuationCharacterization_007

185

TC_SECC_CMN_VTB_AttenuationCharacterization_008

186

TC_SECC_CMN_VTB_AttenuationCharacterization_009

187

TC_SECC_CMN_VTB_AttenuationCharacterization_010

188

TC_SECC_CMN_VTB_AttenuationCharacterization_011

189

TC_SECC_CMN_VTB_AttenuationCharacterization_012

190

TC_SECC_CMN_VTB_AttenuationCharacterization_013

191

TC_SECC_CMN_VTB_AttenuationCharacterization_014

192

TC_SECC_CMN_VTB_AttenuationCharacterization_015

193

TC_SECC_CMN_VTB_AttenuationCharacterization_016

194

TC_SECC_CMN_VTB_AttenuationCharacterization_017

195

TC_SECC_CMN_VTB_AttenuationCharacterization_018

196

TC_SECC_CMN_VTB_AttenuationCharacterization_019

197

TC_SECC_CMN_VTB_CmValidate_010

198

TC_SECC_CMN_VTB_CmSlacMatch_001

199

TC_SECC_CMN_VTB_CmSlacMatch_003

200

TC_SECC_CMN_VTB_CmSlacMatch_005

201

TC_SECC_CMN_VTB_CmSlacMatch_007

202

TC_SECC_CMN_VTB_CmSlacMatch_009

203

TC_SECC_CMN_VTB_CmSlacMatch_011

204

TC_SECC_CMN_VTB_CmSlacMatch_013

205

TC_SECC_CMN_VTB_CmSlacMatch_015

206

TC_SECC_CMN_VTB_CmSlacMatch_017

207

TC_SECC_CMN_VTB_CmSlacMatch_019

208

TC_SECC_CMN_VTB_CmSlacMatch_021

209

TC_SECC_CMN_VTB_CmSlacMatch_023

210

TC_SECC_CMN_VTB_PLCLinkStatus_001

211

TC_SECC_CMN_VTB_PLCLinkStatus_002

212

TC_SECC_CMN_VTB_PLCLinkStatus_003

213

TC_SECC_CMN_VTB_PLCLinkStatus_004

214

TC_SECC_CMN_VTB_PLCLinkStatus_005

215

TC_SECC_DC_VTB_PLCLinkStatus_001

216

TC_SECC_DC_VTB_PLCLinkStatus_002

217

TC_SECC_DC_VTB_PLCLinkStatus_003

218

TC_SECC_DC_VTB_PLCLinkStatus_004

219

TC_SECC_DC_VTB_PLCLinkStatus_005

220

TC_SECC_DC_VTB_PLCLinkStatus_006

221

TC_SECC_DC_VTB_PLCLinkStatus_007

 

Table 3. DIN 70121 European Standard Protocol Conformance

Serial Number

Project Name

Remarks

1

TC_SECC_VTB_CmSlacParm_001

 

2

TC_SECC_VTB_CmSlacParm_002

 

3

TC_SECC_VTB_CmSlacParm_003

 

4

TC_SECC_VTB_CmSlacParm_004

 

5

TC_SECC_VTB_AttenuationCharacterization_001

 

6

TC_SECC_VTB_AttenuationCharacterization_002

 

7

TC_SECC_VTB_AttenuationCharacterization_003

 

8

TC_SECC_VTB_AttenuationCharacterization_004

 

9

TC_SECC_VTB_AttenuationCharacterization_005

 

10

TC_SECC_VTB_AttenuationCharacterization_006

 

11

TC_SECC_VTB_AttenuationCharacterization_007

 

12

TC_SECC_VTB_AttenuationCharacterization_008

 

13

TC_SECC_VTB_AttenuationCharacterization_009

 

14

TC_SECC_VTB_AttenuationCharacterization_010

 

15

TC_SECC_VTB_AttenuationCharacterization_011

 

16

TC_SECC_VTB_AttenuationCharacterization_012

 

17

TC_SECC_VTB_AttenuationCharacterization_013

 

18

TC_SECC_VTB_AttenuationCharacterization_014

 

19

TC_SECC_VTB_AttenuationCharacterization_015

 

20

TC_SECC_VTB_AttenuationCharacterization_016

 

21

TC_SECC_VTB_AttenuationCharacterization_017

 

22

TC_SECC_VTB_AttenuationCharacterization_018

 

23

TC_SECC_VTB_AttenuationCharacterization_019

 

24

TC_SECC_VTB_AttenuationCharacterization_020

 

25

TC_SECC_VTB_CmSlacMatch_001

 

26

TC_SECC_VTB_CmSlacMatch_003

 

27

TC_SECC_VTB_CmSlacMatch_005

 

28

TC_SECC_VTB_CmSlacMatch_007

 

29

TC_SECC_VTB_CmSlacMatch_009

 

30

TC_SECC_VTB_CmSlacMatch_011

 

31

TC_SECC_VTB_CmSlacMatch_013

 

32

TC_SECC_VTB_CmSlacMatch_015

 

33

TC_SECC_VTB_CmSlacMatch_017

 

34

TC_SECC_VTB_CmSlacMatch_019

 

35

TC_SECC_VTB_CmSlacMatch_021

 

36

TC_SECC_VTB_PLCLinkStatus_001

 

37

TC_SECC_VTB_PLCLinkStatus_002

 

38

TC_SECC_VTB_PLCLinkStatus_003

 

39

TC_SECC_VTB_PLCLinkStatus_004

 

40

TC_SECC_VTB_PLCLinkStatus_005

 

41

TC_SECC_VTB_PLCLinkStatus_006

 

42

TC_SECC_VTB_V2GTPSessionSetup_001

 

43

TC_SECC_VTB_V2GTPSessionSetup_002

 

44

TC_SECC_VTB_V2GTPSessionSetup_003

 

45

TC_SECC_VTB_V2GTPSessionSetup_004

 

46

TC_SECC_VTB_V2GTPSDP_001

 

47

TC_SECC_VTB_SDP_001

 

48

TC_SECC_VTB_SDP_002

 

49

TC_SECC_VTB_SupportedAppProtocol_001

 

50

TC_SECC_VTB_SupportedAppProtocol_002

 

51

TC_SECC_VTB_SupportedAppProtocol_003

 

52

TC_SECC_VTB_SupportedAppProtocol_004

 

53

TC_SECC_VTB_SupportedAppProtocol_005

 

54

TC_SECC_VTB_SessionSetup_001

 

55

TC_SECC_VTB_SessionSetup_002

 

56

TC_SECC_VTB_SessionSetup_003

 

57

TC_SECC_VTB_SessionSetup_004

 

58

TC_SECC_VTB_ServiceDiscovery_001

 

59

TC_SECC_VTB_ServiceDiscovery_002

 

60

TC_SECC_VTB_ServiceDiscovery_003

 

61

TC_SECC_VTB_ServiceDiscovery_004

 

62

TC_SECC_VTB_ServiceDiscovery_005

 

63

TC_SECC_VTB_ServiceDiscovery_006

 

64

TC_SECC_VTB_ServiceDiscovery_007

 

65

TC_SECC_VTB_ServiceDiscovery_008

 

66

TC_SECC_VTB_ServicePaymentSelection_001

 

67

TC_SECC_VTB_ServicePaymentSelection_002

 

68

TC_SECC_VTB_ServicePaymentSelection_003

 

69

TC_SECC_VTB_ServicePaymentSelection_004

 

70

TC_SECC_VTB_ServicePaymentSelection_005

 

71

TC_SECC_VTB_ServicePaymentSelection_006

 

72

TC_SECC_VTB_ServicePaymentSelection_007

 

73

TC_SECC_VTB_ServicePaymentSelection_008

 

74

TC_SECC_VTB_ContractAuthentication_001

 

75

TC_SECC_VTB_ContractAuthentication_002

 

76

TC_SECC_VTB_ContractAuthentication_003

 

77

TC_SECC_VTB_ContractAuthentication_004

 

78

TC_SECC_VTB_ContractAuthentication_005

 

79

TC_SECC_VTB_ContractAuthentication_006

 

80

TC_SECC_VTB_ContractAuthentication_007

 

81

TC_SECC_VTB_ChargeParameterDiscovery_001

 

82

TC_SECC_VTB_ChargeParameterDiscovery_002

 

83

TC_SECC_VTB_ChargeParameterDiscovery_003

 

84

TC_SECC_VTB_ChargeParameterDiscovery_004

 

85

TC_SECC_VTB_ChargeParameterDiscovery_005

 

86

TC_SECC_VTB_ChargeParameterDiscovery_006

 

87

TC_SECC_VTB_ChargeParameterDiscovery_007

 

88

TC_SECC_VTB_ChargeParameterDiscovery_008

 

89

TC_SECC_VTB_ChargeParameterDiscovery_009

 

90

TC_SECC_VTB_CableCheck_001

 

91

TC_SECC_VTB_CableCheck_002

 

92

TC_SECC_VTB_CableCheck_003

 

93

TC_SECC_VTB_CableCheck_004

 

94

TC_SECC_VTB_CableCheck_005

 

95

TC_SECC_VTB_CableCheck_006

 

96

TC_SECC_VTB_CableCheck_007

 

97

TC_SECC_VTB_CableCheck_008

 

98

TC_SECC_VTB_CableCheck_009

 

99

TC_SECC_VTB_CableCheck_010

 

100

TC_SECC_VTB_CableCheck_011

 

101

TC_SECC_VTB_CableCheck_012

 

102

TC_SECC_VTB_CableCheck_013

 

103

TC_SECC_VTB_CableCheck_014

 

104

TC_SECC_VTB_CableCheck_015

 

105

TC_SECC_VTB_CableCheck_016

 

106

TC_SECC_VTB_CableCheck_017

 

107

TC_SECC_VTB_CableCheck_018

 

108

TC_SECC_VTB_CableCheck_019

 

109

TC_SECC_VTB_CableCheck_020

 

110

TC_SECC_VTB_CableCheck_021

 

111

TC_SECC_VTB_CableCheck_022

 

112

TC_SECC_VTB_CableCheck_023

 

113

TC_SECC_VTB_PreCharge_001

 

114

TC_SECC_VTB_PreCharge_002

 

115

TC_SECC_VTB_PreCharge_003

 

116

TC_SECC_VTB_PreCharge_004

 

117

TC_SECC_VTB_PreCharge_005

 

118

TC_SECC_VTB_PreCharge_006

 

119

TC_SECC_VTB_PreCharge_007

 

120

TC_SECC_VTB_PreCharge_008

 

121

TC_SECC_VTB_PowerDelivery_001

 

122

TC_SECC_VTB_PowerDelivery_002

 

123

TC_SECC_VTB_PowerDelivery_003

 

124

TC_SECC_VTB_PowerDelivery_004

 

125

TC_SECC_VTB_PowerDelivery_005

 

126

TC_SECC_VTB_PowerDelivery_006

 

127

TC_SECC_VTB_PowerDelivery_007

 

128

TC_SECC_VTB_PowerDelivery_008

 

129

TC_SECC_VTB_PowerDelivery_009

 

130

TC_SECC_VTB_PowerDelivery_010

 

131

TC_SECC_VTB_PowerDelivery_011

 

132

TC_SECC_VTB_PowerDelivery_012

 

133

TC_SECC_VTB_PowerDelivery_013

 

134

TC_SECC_VTB_PowerDelivery_014

 

135

TC_SECC_VTB_CurrentDemand_001

 

136

TC_SECC_VTB_CurrentDemand_002

 

137

TC_SECC_VTB_CurrentDemand_003

 

138

TC_SECC_VTB_CurrentDemand_004

 

139

TC_SECC_VTB_CurrentDemand_005

 

140

TC_SECC_VTB_CurrentDemand_006

 

141

TC_SECC_VTB_WeldingDetection_001

 

142

TC_SECC_VTB_WeldingDetection_002

 

143

TC_SECC_VTB_WeldingDetection_003

 

144

TC_SECC_VTB_WeldingDetection_004

 

145

TC_SECC_VTB_WeldingDetection_005

 

146

TC_SECC_VTB_WeldingDetection_006

 

147

TC_SECC_VTB_WeldingDetection_007

 

148

TC_SECC_VTB_SessionStop_001

 

149

TC_SECC_VTB_SessionStop_002

 

150

TC_SECC_VTB_SessionStop_003

 

151

TC_SECC_VTB_SessionStop_004

 

152

TC_SECC_VTB_SessionStop_005

 

153

TC_SECC_VTB_SessionStop_006

 

154

TC_SECC_VTB_SessionStop_007

 

155

TC_SECC_VTB_SessionStop_008

 

156

TC_SECC_VTB_SessionStop_009

 

157

TC_SECC_VTB_SessionStop_010

 

158

TC_SECC_VTB_SessionStop_011

 

159

TC_SECC_VTB_SessionStop_012

 

160

TC_SECC_VTB_SessionStop_013

 

 

Table 4. Japanese Standard Inspection Items

Serial Number

Japanese Standard CHAdeMO Test Items

1

General Inspection

2

Appearance Inspection

3

Marking Inspection

4

Basic Composition Inspection

5

Mechanical Switch Equipment Inspection

6

Anti-theft Measures Inspection

7

Functional Test

8

Communication Function Test

9

Charging Connection Device Inspection

10

Locking Device Test

11

Display Function Test

12

Charging Current Response Test

13

Charging Current Decline Rate Test

14

Current Ripple Test

15

Voltage Ripple Test

16

Load Sudden Drop Test

17

Output Current Error Test

18

Output Voltage Error Test

19

Charging Current Control Delay Test

20

Charging Current Decline Rate Test

21

Load Sudden Drop Test

22

Protective Conductor Continuity Check

23

Voltage Measurement Accuracy Test

24

Current Measurement Accuracy Test

25

Connector Lock Detection

26

Insulation Abnormality Simulation Test

27

Battery Overvoltage Protection Test

28

Control Circuit Power Integrity Test

29

Input Function Test

30

Metering Function Test

31

Safety Requirements Test