XL-3604 Wideband Current Transformer Calibrator
The XL-3604 wideband current transformer calibrator is mainly used for the calibration of wideband current transformers. Calibration items include ratio error, phase error, etc.
Product Description
Product Introduction
XL-3604 Wideband Current Transformer Calibrator Mainly used for the calibration of wideband current transformers. Calibration items include ratio error, phase error, etc.
Main Functions
- Supports electronic transformers with small signal output
- Supports calibration of traditional current transformers 1A, 5A and voltage transformers 57.7V, 100V.
- Supports testing the harmonic transfer characteristics of capacitive voltage transformers according to the requirements of "T/CEC 296-2020 Capacitive Voltage Transformer Harmonic Transfer Characteristic Test Technical Specification", supporting calibration of fundamental wave, harmonics (2~50th), and interharmonics (0.1~49.9th).
- Supports calibration of electronic transformers that comply with IEC61850-9-2/LE standard.
Main Features
- Wideband current sensor error (ratio error, phase error) test at DCHz~2.5kHz frequency;
- Power frequency error (ratio error, phase error) test of current sensor;
- 2~40th harmonic error (ratio error, phase error) test of current sensor;
- 2~40th harmonic error (ratio error, phase error) influence test of current sensor;
- Analysis of harmonic content and waveform distortion rate of the secondary output of current sensor, and testing of ratio error and phase error of each harmonic.
Technical Parameters
| 1. Accuracy Class | Class 0.05 |
| 2. Measurement Accuracy | |
| Fundamental Wave Measurement Accuracy | |
| Current Measurement Accuracy | 50mA~6A: 0.05% RD; |
| 10mA~50mA: 0.1% RD; | |
| Standard Input Range | 0~6A (5A standard terminal) |
| 0~100 (100A standard terminal) | |
| Tested Input Range | 0~6A |
| Ratio Error Measurement Accuracy | 30Hz~200Hz: <0.05% |
| 200Hz~1kHz: <0.05% | |
| 1kHz~2.5kHz: <0.1% | |
| Phase Error Measurement Accuracy | 30Hz~200Hz: <2′ |
| 200Hz~1kHz: <5′ | |
| 1kHz~2.5kHz: <10′ | |
| DC Measurement Accuracy | 0.10% |
| Current Input Terminal Impedance | Not greater than 0.1Ω (AC mode), not greater than 5Ω (DC mode) |
| Measurement Frequency Range | DC~2.5kHz |
| 3. Human-Machine Interface | |
| Display | TFT LCD resolution 800*600 |
| Operation | Touch screen operation, industrial computer has USB port, can connect USB mouse and keyboard |
| Dimensions | 470mm×330mm×200mm |
| Total Weight | 10kg |
| 4. Environmental Conditions | |
| Power Supply Voltage | AC 220V±10% 50 Hz |
| Ambient Air Temperature | (-10℃ ~ 55℃) |
| Maximum Relative Humidity | <85% |