XL-809DPT DC Distribution Network Voltage Sensor Calibration System

XL-809DPT DC distribution network voltage sensor calibration system, equipped with a transformer calibrator, 10kV fully shielded DC standard divider, and programmable adjustable DC high voltage source. It features a high degree of automation and meets the current sensor verification regulations.

Product Description

Main Functions

  • Implements ratio difference calibration for DC distribution network voltage sensors.
  • The DC voltage sensor calibration system integrates traditional equipment (components) and is equipped with a transformer calibrator, 10kV fully shielded DC standard voltage divider, and programmable adjustable DC high voltage source. It has a high degree of automation and meets current sensor verification regulations.
  • All equipment (components) within the device can be individually sent for inspection according to existing verification regulations.
  • Equipped with primary voltage monitoring instruments that can display primary voltage.
  • Large screen display with built-in touch screen, full Chinese operation prompts, easy operation, real-time display of measurement data, and statistical analysis.
  • Can display the waveform of the sensor being calibrated in real time to monitor waveform distortion of the sensor under test.
  • Calibration schemes can be freely edited as needed to achieve fully automatic calibration.
  • Can generate and print test reports based on customer-provided templates, which can be freely edited.
  • This product has strong adaptability and scalability, supporting future upgrades.

 

Technical Specifications

1. Transformer Calibrator Specifications
Accuracy Class Class 0.05
Standard and Tested Input Range 0~10V
Standard and Tested Input Ranges 0.15V, 0.5V, 2V, 10V
Measurement Range 1%-120% Un
Input Impedance ≥100MΩ
Load Resistance Ranges 20kΩ, 50kΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ
Load Accuracy 3%
2. Programmable Adjustable DC High Voltage Source
Output Range 0-10kV
Accuracy 1%RD
Stability Better than 0.1% (after thermal stabilization)
Ripple Factor Better than 0.1% RMS
3. 10kV Fully Shielded DC Standard Voltage Divider
Input Range 0-10kV
Standard Voltage Transformer Specifications 10kV: 10V
Standard Voltage Transformer Accuracy Class 0.02
4. Other Specifications
Industrial Computer Parameters Display: 19 inches
Processor: I5
4GB Memory
Power Supply AC220V±5%, 50Hz
Total Power Consumption < 1000VA
Warm-up Time <15 minutes
Weight Approximately 65kg
Operating Temperature -5℃ to +40℃
Relative Humidity ≤80% (no condensation or corrosive gases)

Product Document

File Name

Update Time

Related Products

XL-809DCT DC Distribution Network Current Sensor Calibration System


The current sensor calibration system integrates traditional equipment (components) into one unit, built-in with a mutual inductor calibrator, standard current sensor, and programmable DC high current source. It features a high degree of automation and meets the current mutual inductor verification regulations.