XL-3642 Low Frequency Current Transformer Calibrator

The XL-3642 low-frequency current transformer calibrator can test electromagnetic (low-frequency) current transformers with a rated frequency of 15Hz~65Hz (such as 20Hz) that comply with "GB/T 20840.2 Instrument Transformers Part 2: Supplementary Technical Requirements for Current Transformers" and "GB/T 20840.8 Instrument Transformers Part 8: Electronic Current Transformers."

Product Description

Product Introduction                              

XL-3642 Low Frequency Current Transformer Calibrator It can test electromagnetic (low frequency) current transformers with rated frequencies from 15Hz to 65Hz (such as 20Hz) that comply with "GB/T 20840.2 Transformers Part 2: Supplementary Technical Requirements for Current Transformers" and "GB/T 20840.8 Transformers Part 8: Electronic Current Transformers." Based on the digital comparison transformer calibration principle, the core uses a dual-CPU architecture, offering powerful functions. With a 24-bit AD chip and 512 times oversampling technology, the bandwidth is greatly expanded and measurement accuracy is improved. At the same time, an FIR filter is used to enhance dynamic range and signal-to-noise ratio. The independently developed human-machine interaction software adopts a popular design, making it simple and convenient to use.

 

Main Functions

  • Error (ratio error, phase error) test of low-frequency voltage/current transformers at 15Hz~30Hz frequency;
  • Power frequency error (ratio error, phase error) test of voltage/current transformers;
  • 2nd to 40th harmonic error (ratio error, phase error) test of voltage/current transformers;
  • Influence test of 2nd to 40th harmonic error (ratio error, phase error) of voltage/current transformers;
  • DC voltage/current transformer error test;
  • Harmonic content analysis and waveform distortion rate calculation of the secondary output of voltage/current transformers, and testing of ratio error and phase error for each harmonic order;

 

Technical Specifications

1. Accuracy Class
0.05 Class   ( Ratio Error < 0.05% , Phase Error < 2'
2. Measurement Accuracy
Fundamental Measurement Accuracy
Current Measurement Accuracy 50mA~6A 0.05%RD
10mA~50mA 0.1%RD
Voltage Measurement Accuracy 10V~120V 0.05%RD
Input Range 0~120V 0~6A
Ratio Error Measurement Accuracy 0.05%
Phase Error Measurement Accuracy 2 '
DC Measurement Accuracy 0.10%
Current Input Terminal Impedance Not greater than 0.1Ω (AC mode), not greater than 5Ω (DC mode)
Measurement Frequency Range 15~50Hz
3. Human-Machine Interface
Display TFT LCD Resolution 800*600
Operation Touch screen operation, industrial computer has USB port, can connect USB mouse and keyboard
Dimensions 470mm×330mm×200mm
Total Weight 10kg
5) Environmental Conditions
Power Supply Voltage AC 220V ± 10% 50 Hz
Ambient Air Temperature (-10 ~ 55 )
Maximum Relative Humidity <85%

Product Document

File Name

Update Time

Related Products

XL-3604 Wideband Current Transformer Calibrator


The XL-3604 wideband current transformer calibrator is mainly used for the calibration of wideband current transformers. Calibration items include ratio error, phase error, etc.

XL-3605 Wide Range Current Transformer Calibrator


The XL-3605 wide-range current transformer calibrator is mainly used for calibrating the phase angle difference and ratio difference of current transformers under signals including power frequency current, harmonics, and other frequency signals as well as full-wave signals. Calibration items include ratio difference, phase angle difference, harmonic analysis, and harmonic accuracy verification.

XL-3602 DC Current Transformer Tester


The XL-3602 DC-resistant transformer calibrator is mainly used for DBI DC bias-resistant low-voltage current transformer calibration. It features power frequency error testing, power frequency superimposed DC component testing, sine half-wave testing, and harmonic testing functions.