XL-3610T3 Micro Current Transformer Calibration System

The XL-3610T3 miniature current transformer calibration system mainly consists of a digital synthesized wave AC/DC high current source, a miniature current transformer calibrator, and a calibration platform. It supports secondary output as a small voltage signal (0~7V) for miniature current transformers and current output (0~100mA) for miniature current transformers.

Product Description

Product Introduction

XL-3610T3 Micro Current Transformer Calibration System Mainly composed of a digital synthesized AC/DC high current source, micro current transformer calibrator, and calibration bench. It features a dual-CPU architecture core with powerful functions, greatly expanded bandwidth using a 24Bit AD chip and 512 times oversampling technology, improving measurement accuracy. It also uses an FIR filter to enhance dynamic range and signal-to-noise ratio. The independently developed human-machine interaction software adopts a popular design, making it simple and convenient to use. Supports secondary output as voltage small signal (0~7V) output micro current transformers and current output (0~100mA) micro current transformers.

 

Features

 

  • Three meter positions design, can test three micro current transformers at one time;
  • Basic error and composite error testing of micro current transformers at power frequency;
  • Error and composite error testing of micro current transformers under power frequency current superimposed with DC component;
  • Error and composite error testing of micro current transformers under sinusoidal half-wave;
  • Harmonic content analysis and waveform distortion rate calculation of secondary output of micro current transformers, and can test ratio error and phase error of each harmonic;
  • Fully automatic testing according to the test plan, and automatically saves test data;
  • Automatically controls the high current source to output different calibration points during automatic testing;
  • Automatically generates test reports, which can be edited according to user templates;
  • The high current source can superimpose DC output and output sinusoidal half-wave on the fundamental wave.

 

Technical Specifications

1. Overall Specifications
Calibrator Accuracy Class Class 0.05
Digital Synthesized AC/DC High Current Source Accuracy 0.01
Calibration Bench Dimensions (L×D×H) 2110mm×780mm×960mm
Weight Approximately 100 kg
Working Environment Should have good ventilation conditions
Ambient Temperature -10℃ ~ 55℃
Relative Humidity < 85% (no condensation or corrosive gases)
Power Supply Please refer to the power supply specifications of each module
2. Micro Current Transformer Calibrator
Standard Input Range 10mA~100A
Tested Input Range Voltage Input Type: 0.5mV~7V
Current Input Type: 50uA~100mA
Ratio Error Measurement Accuracy 0.02% (200mV~7V)
0.05% (20mV~200mV)
0.1% (1mV~20mV)
0.5% (0.5mV~1mV)
Phase Error Measurement Accuracy 2 minutes (20mV~7V)
4 minutes (1mV~20mV)
Measurement Frequency Range 45Hz~65Hz
3. Harmonic Measurement Accuracy
Harmonic Order 2~4th 5~6th 7~10th 11~25th 26~41st
Harmonic Ratio Difference Measurement Accuracy (%) 0.1 0.2 0.5 1 2
Harmonic Phase Difference Measurement Accuracy (°) 0.2 0.5 1 2 3
Power Supply AC 220 (1±10%) V (50 ±0.5) Hz
4. Digital Synthesized AC/DC High Current Source
Power Frequency Current Accuracy 1%
Frequency Output Range 0~2050Hz (0~50A)
0~1050Hz (0~100A)
Output Current Range (Power Frequency) 10mA~100A
Terminal Voltage Value 3.7V
Waveform Distortion (Power Frequency) <1%
Output Stability Better than 0.2% / min
Power Supply AC 220 (1±10%) V (50 ±0.5) Hz (MAX 13A)


 

Product Document

File Name

Update Time

Related Products

XL-3600T3 DC Current Sensor Calibration Bench


The XL-3600T3 DC current sensor calibration bench mainly consists of a high-power DC current source, a DC current standard sensor, a DC current sensor calibrator, and the calibration bench body. It supports error calibration for primary currents of 0~1000A and secondary outputs of voltage type (0~7V) or current type (0~100mA) DC current sensors.

XL-3610T6 Micro Current Transformer Calibration System


The XL-3610T6 miniature current transformer calibration system product is designed in accordance with standards such as "Q/GDW11179.15-2015 Technical Specifications for Components Used in Electric Energy Meters: Current Transformers" and is used for the calibration of miniature current transformers for electric energy meters.

XL-3620T6 Wide Range Current Transformer Calibration System


The XL-3620T6 wide-range current transformer calibration system meets the requirements of the State Grid Corporation of China's enterprise standard "QGDW10572.1-2020 Technical Specification for Measuring Transformers Part 1: Low Voltage Current Transformers" and is capable of testing the ratio error and phase displacement of wide-range SS grade current transformers.

XL-3600T6 Anti-DC Transformer Calibration System


The XL-3600T6 Anti-DC Transformer Verification System can test the power frequency ratio error angle, power frequency half-wave error, and power frequency superimposed DC error of low-voltage current transformers resistant to DC bias.

XL-3600T12H High-Precision Current Sensor Calibration System


The XL-3600T12H high-precision current sensor calibration system can test the angle difference, ratio difference, and DC error of power frequency or harmonic currents of current sensors. It can provide ±15V power supply to each device under test and measure the load current on the power supply. It allows setting abnormal threshold values for the load current. The system uses a program-controlled digital synthesized current source and a digital comparative transformer calibrator, featuring high automation and good testing accuracy. It is suitable for use in regional metering centers, research institutions, and manufacturers of high-precision current sensors.

XL-3611 AC/DC Current Transformer and Sensor Testing Bench


The XL-3611 AC/DC current transformer and sensor testing bench consists of a current source, AC calibrator, DC calibrator, leakage current calibrator, and calibration system software.

Product Inquiry

Our staff will contact you within 24 hours (working days)