XL-3611 AC/DC Current Transformer and Sensor Testing Bench

The XL-3611 AC/DC current transformer and sensor testing bench consists of a current source, AC calibrator, DC calibrator, leakage current calibrator, and calibration system software.

Product Description

Product Introduction  

 

XL-3611 AC/DC Current Transformer and Sensor Test Bench Composed of a current source, AC calibrator, DC calibrator, leakage current calibrator, and calibration system software, its core adopts a dual-CPU architecture with powerful functions. Using a 24Bit AD chip and 512 times oversampling technology greatly expands the bandwidth and improves measurement accuracy. At the same time, an FIR filter is used to improve dynamic range and signal-to-noise ratio. The independently developed human-machine interaction software adopts a popular design, making it simple and convenient to use.

 

Main Features    

 

Technical Specifications

 

1. Current Source
Output Range High Current 100mA~600A (RMS)
Low Current 40uA~1A (RMS)
Accuracy 1%
Test Bench Dimensions (L×D×H) 2216mm×900mm×1230mm
Weight About 80 kg
Working Environment Should have good ventilation conditions
Ambient Temperature -10℃ ~ 55℃
Relative Humidity < 85% (no condensation or corrosive gases)
Power Supply Three-phase four-wire (3×220V), 15kVA (at maximum output)
2. AC Calibration
Input Range to be Tested Voltage 10mV~6V (RMS)
Current 10mA~6A (RMS)
Ratio Error Measurement Accuracy 0.05%
Phase Error Measurement Accuracy 2′
Measurement Frequency Range 20Hz~440Hz
3. Harmonic Measurement Accuracy
Harmonic Order 2~4th 5~6th 7~10th 11~25th 26~50th
Harmonic Ratio Error Measurement Accuracy (%) 0.1 0.2 0.5 1 2
Harmonic Phase Difference Measurement Accuracy (°) 0.2 0.5 1 2 3
4. DC Calibration
Input Range to be Tested Voltage 10mV~8V (RMS)
Current 2mA~1A (RMS)
Ratio Error Measurement Accuracy 0.05%
DC Current Measurement Accuracy 0.1%
Power Supply AC 220V±10% 50 Hz
5. Leakage Current Calibration
Input Range to be Tested Voltage 10mV~6V (RMS)
Current 40uA~24mA (RMS)
Ratio Error Measurement Accuracy 0.05%
Phase Error Measurement Accuracy 2′
Measurement Frequency Range 20Hz~440Hz
6. Harmonic Measurement Accuracy
Harmonic Order 2~4th 5~6th 7~10th 11~25th 26~50th
Harmonic Ratio Error Measurement Accuracy (%) 0.1 0.2 0.5 1 2
Harmonic Phase Difference Measurement Accuracy (°) 0.2 0.5 1 2 3

Product Document

File Name

Update Time

Related Products

XL-3600T3 DC Current Sensor Calibration Bench


The XL-3600T3 DC current sensor calibration bench mainly consists of a high-power DC current source, a DC current standard sensor, a DC current sensor calibrator, and the calibration bench body. It supports error calibration for primary currents of 0~1000A and secondary outputs of voltage type (0~7V) or current type (0~100mA) DC current sensors.

XL-3610T3 Micro Current Transformer Calibration System


The XL-3610T3 miniature current transformer calibration system mainly consists of a digital synthesized wave AC/DC high current source, a miniature current transformer calibrator, and a calibration platform. It supports secondary output as a small voltage signal (0~7V) for miniature current transformers and current output (0~100mA) for miniature current transformers.

XL-3610T6 Micro Current Transformer Calibration System


The XL-3610T6 miniature current transformer calibration system product is designed in accordance with standards such as "Q/GDW11179.15-2015 Technical Specifications for Components Used in Electric Energy Meters: Current Transformers" and is used for the calibration of miniature current transformers for electric energy meters.

XL-3620T6 Wide Range Current Transformer Calibration System


The XL-3620T6 wide-range current transformer calibration system meets the requirements of the State Grid Corporation of China's enterprise standard "QGDW10572.1-2020 Technical Specification for Measuring Transformers Part 1: Low Voltage Current Transformers" and is capable of testing the ratio error and phase displacement of wide-range SS grade current transformers.

XL-3600T6 Anti-DC Transformer Calibration System


The XL-3600T6 Anti-DC Transformer Verification System can test the power frequency ratio error angle, power frequency half-wave error, and power frequency superimposed DC error of low-voltage current transformers resistant to DC bias.

XL-3600T12H High-Precision Current Sensor Calibration System


The XL-3600T12H high-precision current sensor calibration system can test the angle difference, ratio difference, and DC error of power frequency or harmonic currents of current sensors. It can provide ±15V power supply to each device under test and measure the load current on the power supply. It allows setting abnormal threshold values for the load current. The system uses a program-controlled digital synthesized current source and a digital comparative transformer calibrator, featuring high automation and good testing accuracy. It is suitable for use in regional metering centers, research institutions, and manufacturers of high-precision current sensors.

Product Inquiry

Our staff will contact you within 24 hours (working days)