XL-3611 AC/DC Current Transformer and Sensor Testing Bench
The XL-3611 AC/DC current transformer and sensor testing bench consists of a current source, AC calibrator, DC calibrator, leakage current calibrator, and calibration system software.
Product Description
Product Introduction
XL-3611 AC/DC Current Transformer and Sensor Test Bench Composed of a current source, AC calibrator, DC calibrator, leakage current calibrator, and calibration system software, its core adopts a dual-CPU architecture with powerful functions. Using a 24Bit AD chip and 512 times oversampling technology greatly expands the bandwidth and improves measurement accuracy. At the same time, an FIR filter is used to improve dynamic range and signal-to-noise ratio. The independently developed human-machine interaction software adopts a popular design, making it simple and convenient to use.
Main Features
- Basic error and basic error tests under various influencing factors;
- Short-term zero stability test;
- Current overload test;
- Response time test;
- Fully automatic testing according to the test plan, with automatic saving of test data;
- Automatically generate test reports, which can be edited according to user templates.
Technical Specifications
1. Current Source | ||||||
Output Range | High Current | 100mA~600A (RMS) | ||||
Low Current | 40uA~1A (RMS) | |||||
Accuracy | 1% | |||||
Test Bench | Dimensions (L×D×H) | 2216mm×900mm×1230mm | ||||
Weight | About 80 kg | |||||
Working Environment | Should have good ventilation conditions | |||||
Ambient Temperature | -10℃ ~ 55℃ | |||||
Relative Humidity | < 85% (no condensation or corrosive gases) | |||||
Power Supply | Three-phase four-wire (3×220V), 15kVA (at maximum output) | |||||
2. AC Calibration | ||||||
Input Range to be Tested | Voltage | 10mV~6V (RMS) | ||||
Current | 10mA~6A (RMS) | |||||
Ratio Error Measurement Accuracy | 0.05% | |||||
Phase Error Measurement Accuracy | 2′ | |||||
Measurement Frequency Range | 20Hz~440Hz | |||||
3. Harmonic Measurement Accuracy | ||||||
Harmonic Order | 2~4th | 5~6th | 7~10th | 11~25th | 26~50th | |
Harmonic Ratio Error Measurement Accuracy (%) | 0.1 | 0.2 | 0.5 | 1 | 2 | |
Harmonic Phase Difference Measurement Accuracy (°) | 0.2 | 0.5 | 1 | 2 | 3 | |
4. DC Calibration | ||||||
Input Range to be Tested | Voltage | 10mV~8V (RMS) | ||||
Current | 2mA~1A (RMS) | |||||
Ratio Error Measurement Accuracy | 0.05% | |||||
DC Current Measurement Accuracy | 0.1% | |||||
Power Supply | AC 220V±10% 50 Hz | |||||
5. Leakage Current Calibration | ||||||
Input Range to be Tested | Voltage | 10mV~6V (RMS) | ||||
Current | 40uA~24mA (RMS) | |||||
Ratio Error Measurement Accuracy | 0.05% | |||||
Phase Error Measurement Accuracy | 2′ | |||||
Measurement Frequency Range | 20Hz~440Hz | |||||
6. Harmonic Measurement Accuracy | ||||||
Harmonic Order | 2~4th | 5~6th | 7~10th | 11~25th | 26~50th | |
Harmonic Ratio Error Measurement Accuracy (%) | 0.1 | 0.2 | 0.5 | 1 | 2 | |
Harmonic Phase Difference Measurement Accuracy (°) | 0.2 | 0.5 | 1 | 2 | 3 |
Product Document
File Name
Update Time
Related Products
XL-3600T3 DC Current Sensor Calibration Bench
XL-3610T3 Micro Current Transformer Calibration System
XL-3610T6 Micro Current Transformer Calibration System
XL-3620T6 Wide Range Current Transformer Calibration System
XL-3600T6 Anti-DC Transformer Calibration System
XL-3600T12H High-Precision Current Sensor Calibration System
Product Inquiry