XL-221 Single-phase Dynamic Distortion Standard Power Source

The XL-221 single-phase dynamic distortion standard power source can output single-phase AC/DC voltage and single-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, as well as superimpose harmonics up to the 100th order, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

Product Description

Product Introduction              

         

XL-221 Single-phase Dynamic Distortion Standard Power Source Can output single-phase AC/DC voltage and single-phase AC/DC current, with voltage and current capable of outputting DC, square wave, triangle wave, sine wave, and superimposed harmonics up to the 100th order, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions. It can be used in scenarios requiring complex waveform signal output, such as dynamic performance testing of electric energy meters, transformer testing, harmonic analysis, etc. Using the XL-221 single-phase dynamic waveform power source, many previously impossible tasks can be easily accomplished, such as dynamic performance testing of electric energy meters; performance indicator testing of sampling devices under various complex waveforms; outputting various high-precision signal waveforms that were previously unattainable on standard sources.

 

Main Functions                   

  • According to the JJG1106-2015 Static Harmonic Active Energy Meter Verification Regulation, T/CIMA 0020-2020 AC Energy Meter Dynamic Performance Testing Device, T/CIMA 0021-2020 Harmonic Active Energy Meter Testing Device , it can serve as an AC standard voltage source, AC standard current source, and AC standard power source, suitable for dynamic/harmonic energy detection.
  • Voltage Output Range 30~264V, 0-3KHz , can be used as a wide-frequency AC standard voltage source, capable of verifying and calibrating the harmonic/dynamic performance of AC voltmeters.
  • Current Output Range 10mA-12A, 0-2.5KHz , can be used as a wide-frequency AC standard current source, capable of verifying and calibrating the harmonic/dynamic performance of AC ammeters.
  • Built-in error calculation module, serving as a standard power source, meeting the detection requirements of dynamic/harmonic related meters, power quality analysis, non-intrusive monitoring, and other harmonic/dynamic metering devices.

Main Features

  • High Accuracy: Best output accuracy level for power/energy is 0.05, best accuracy level for voltage and current is 0.05, best harmonic output accuracy is 0.2%, best frequency accuracy is 0.005Hz, suitable for dynamic/harmonic energy detection and calibration.
  • Wide Output Range: 30~264V, 10mA-12A, fundamental frequency 0-3KHz, capable of outputting various transient, dynamic, harmonic, simple harmonic, DC, AC superimposed low-frequency oscillation waveforms, serving as standard voltage source, standard current source, and standard power source, meeting the detection and calibration needs of dynamic/harmonic related meters, power quality analysis, non-intrusive monitoring, and other harmonic/dynamic metering devices.
  • Waveform Recording and Playback: The device supports on-site waveform recording and playback functions, allowing repeated playback of a waveform segment or long-term playback of continuous recorded waveform files in Comtrade format. This function enables laboratory simulation of field environment testing and verification for the device under test.
  • Various Waveform Editing Methods: Dynamic waveform output supports formula editing with built-in common mathematical formulas such as trigonometric functions and arithmetic operations; waveform file download allows direct output of pre-edited waveform files, including all waveforms in IEC62052 appendix and waveforms required by IR46 testing; harmonic output allows editing output waveforms by harmonic content and order; hand-drawn waveform output enables arbitrary waveform fitting by hand-drawing waveform lines; suitable for research and development testing.
  • Synchronous Trigger Output Function: Equipped with a synchronous input interface, it can start output triggered by an external synchronous signal or track external periodic trigger signals for zero-cross synchronization output, outputting single/multiple cycles or continuous output. This function can be used to achieve phase-synchronized output among multiple devices.
  • Excellent Harmonic Output Capability: The device has powerful fundamental wave superimposed harmonic output capability, with a maximum output of the 63rd harmonic, supporting arbitrary multiple superposition of each harmonic order, with output content adjustable within the output range, exceeding 100%, supporting various output states such as voltage dips and unbalance for power quality analysis.
  • High Frequency Resolution: Equipped with DDS digital frequency synthesis function, capable of precise frequency modulation, accurately outputting frequencies from 0 to 3KHz with a frequency resolution of 0.002Hz.
  • Low Load Regulation: The power amplifier adopts hardware closed-loop deep negative feedback technology, with adjustment time from no load to full load at millisecond level, typical load regulation rate less than 0.01%.
  • Low Waveform Distortion: 50,000 points per cycle, industry standard is 360-3600 points, typical distortion is 0.03%, industry standard is 0.2%.
  • Human-Machine Interaction, Simple and Flexible: Equipped with a large touchscreen display, clear and intuitive value display, with multiple interfaces including RJ45, RS232, USB, facilitating the construction of automated test systems.

Technical Specifications

                          

Single-phase Voltage Output Frequency Accuracy
Name Specification Range Remarks Frequency accuracy of the lowest output phase: 2ppm, other phase accuracies as per the table below:
DC Output Range 30-220V (Max: 264V) Customizable Frequency Voltage (Accuracy Hz) Current (Accuracy Hz)
AC Output Range 30-220V (Max: 264V) Customizable 0.001~60Hz 0.002 0.005
AC Frequency Range 0.001-3KHz   60~100Hz 0.02 0.02
Harmonic Output Range 2-63 times   100~1000Hz 0.5 0.5
Voltage output accuracy Better than 0.05%   1000~2000Hz 5 5
Harmonic output accuracy Better than 0.2%   1000~5000Hz 50 50
Stability Better than 0.01%   Accuracy level: The frequency step size at each frequency point within this range. With this step size, every frequency value within the range can be adjusted, meaning the actual frequency adjustment step is better than the accuracy level, and the smaller the frequency, the smaller the adjustment step.
Power 20W   Harmonic waveform distortion
Continuous output capability I>=80mA, Udc<50V
I>=150mA, 50V I>=200mA, 100V I>=100mA, 50V
 
The higher the output voltage, the greater the output current Name Voltage Current
AC 50Hz Better than 0.05% Better than 0.05%
Port voltage value 264V AC   Note: Waveform distortion is measured at the limit value of each gear. When the output at this gear is less than the limit value, the waveform distortion will increase.
DC voltage gear 220V   Harmonic content rate
AC voltage output gear 220V   Content rate (fundamental wave 50Hz) Voltage Current
Annual stability 100ppm/year   10% Better than 0.05% Better than 0.05%
Note: To ensure output accuracy, the output current needs to be kept within the limit; otherwise, the accuracy may not meet the required specifications. 50% Better than 0.05% Better than 0.05%
Single-phase current output 100% Better than 0.05% Better than 0.05%
Name Specification Range Remarks Load regulation rate
DC Output Range 0-10A DC (Max: 12A) Customizable Item (full load) Specification Range
AC Output Range 0-10A DC (Max: 12A) Customizable AC voltage output Better than 0.05%
AC Frequency Range 0.001-2.5KHz   DC voltage output Better than 0.05%
Harmonic Output Range 2-63 times   AC current output Better than 0.05%
Current output accuracy Better than 0.05%   DC current output Better than 0.05%
Harmonic output accuracy Better than 0.2% RG   Current load less than or equal to 2 ohms.
Stability Better than 0.05%   Other parameters
Single-phase power 20W   Operating voltage AC 220V±5% 50Hz
Continuous output capability I<=10A AC   Total power consumption No load: 120W, full load: 270W
I<=10A DC   Preheating time <30 minutes
Output port voltage value 2.5V   Operating temperature -10℃ to 55℃
DC current gear 0.01, 0.02, 0.2, 0.4, 2, 10 (A)   Relative humidity ≤85% non-corrosive gas
AC current output gear 0.01, 0.02, 0.2, 0.4, 2, 10 (A)   Dimensions 517 mm * 485.8 mm * 214.8 mm (L*W*H)
Annual stability 100ppm/year   Total weight 21KG

Product Document

File Name

Update Time

Related Products

XL-3203 Three-Phase Harmonic Standard Power Source


The XL-3203 three-phase harmonic standard power source can be used as a dynamic/harmonic standard voltage source, dynamic/harmonic standard current source, dynamic/harmonic standard power source, AC/DC standard power source, and power quality test standard source. Single/three-phase output options are available, voltage output DC-5KHz, current output 0-2.5KHz, accuracy level 0.1/0.05.

XL-3213 Three-Phase Dynamic Distortion Standard Power Source


The XL-3213 three-phase dynamic distortion standard power source (hereinafter referred to as XL-3213) can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, superimposed harmonics, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

XL-803R Three-Phase Multifunction Standard Meter


The XL803R three-phase multifunction standard meter can simultaneously measure parameters such as three-phase voltage, current, frequency, phase, active power, reactive power, apparent power, and can also measure waveform distortion and harmonics from 2nd to 50th order.

XL-3003DZ-D Small Current Low Power Factor Standard Electric Energy Meter


The XL-3003DZ-D small current low power factor standard electric energy meter is suitable for power departments, enterprises, and research institutions in the power system that need to measure and verify the metering performance of small current low power factor. It is also suitable for other occasions requiring measurement and verification with a high-precision standard meter for small current low power factor. This device features high safety, ease of operation, a large touchscreen for control and display, and remote control capabilities.

XL-3200T6 AC Electric Energy Meter Dynamic Performance Testing Device


The XL-3200T6 dynamic table calibration device can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, various harmonic superpositions, fundamental wave superimposed with low-frequency oscillation, and custom waveforms.

XL-3223 Three-Phase Dynamic Waveform Standard Electric Energy Meter


XL-3223 Three-phase dynamic waveform standard electric energy meter series products can be used as AC standard meters and harmonic standard meters. Single/three-phase measurement is optional, harmonic measurement range is 2-50 times, accuracy level is 0.05, and harmonic accuracy is 0.2 level.

XL-3203A Three-Phase Harmonic Standard Power Source


The XL-3203A three-phase harmonic standard power source (hereinafter referred to as XL-3203A) can output single-phase AC and DC current. The current output can be sine wave, superimposed DC, DC, half-wave, and various harmonic superpositions. The frequency output range is DC-1.2kHz, suitable for occasions requiring complex power waveform signal output.

Product Inquiry

Our staff will contact you within 24 hours (working days)