XL-3003DZ-D Small Current Low Power Factor Standard Electric Energy Meter

The XL-3003DZ-D small current low power factor standard electric energy meter is suitable for power departments, enterprises, and research institutions in the power system that need to measure and verify the metering performance of small current low power factor. It is also suitable for other occasions requiring measurement and verification with a high-precision standard meter for small current low power factor. This device features high safety, ease of operation, a large touchscreen for control and display, and remote control capabilities.

Product Description

Product Introduction
 

XL-3003DZ-D Small Current Low Power Factor Standard Electric Energy Meter Designed according to standards such as "JJG 597-2005 Verification Regulations for AC Electric Energy Meter Verification Devices" and "JJG 597-202x Verification Regulations for AC Electric Energy Meter Verification Devices." The current JJG 597-2005 standard sets the lower limit for current measurement at 10mA and power factor measurement at 0.5. Compared to JJG 597-2005, the new JJG 597-202x standard requires testing at a lower current measurement limit of 0.3mA and a power factor measurement limit of 0.25. The XL-3003DZW has an accuracy class of 0.02, using a 1G MAC-based DSP, a high-speed embedded controller, and a 24-bit high-precision ADC. It can measure power frequency (45Hz–65Hz) frequency, amplitude, phase, and active energy, perform harmonic power (voltage, current) combined measurements, with a minimum test current of 0.3mA and a minimum power factor of 0.1. It is suitable for power departments, enterprises, and research institutions that need to measure and verify small current and low power factor metering performance in power systems, as well as other occasions requiring high-precision standard meters for small current and low power factor measurement and verification. This device features high safety, ease of operation, a large touchscreen for control and display, and remote control capabilities.  

 

Main Functions

 

  • High measurement accuracy, designed according to standards such as "JJG 597-2005 Verification Regulations for AC Electric Energy Meter Verification Devices" and "JJG 597-202x Verification Regulations for AC Electric Energy Meter Verification Devices," with an accuracy class of 0.02. Supports power and energy measurement performance testing within voltage range 0-100V, current range 0.3mA-0.3A, and power factor range 0.1-1.0.
  • Small current and low power factor metering, supporting power and energy measurement testing at a minimum current of 0.3mA and minimum power factor of 0.1.
  • Automatic measurement switching: within the measurement range, voltage and current are input through a single terminal set, with full-range automatic gear switching to ensure measurement accuracy across the range.
  • 2 to 50 harmonic measurements, meeting testing requirements of standards such as JJG1106-2015, AC dynamic performance, and IR46.
  • 24-bit high-speed ADC: uses industry-leading 24-bit ADC chips and multi-core DSP processors with large-capacity DDR memory, offering high sampling rate, strong computing power, and high accuracy.
  • High annual stability: uses high-precision imported components, with a typical annual stability value of 60ppm, allowing long-term use without calibration.
  • Measurement value statistical analysis function: can statistically analyze maximum, minimum, variation, and standard deviation of amplitude and power, helping analyze short-term stability and trends.
  • Convenient human-machine interaction: equipped with a large touchscreen display, clear and intuitive value display, and multiple interfaces including RJ45, RS232, and USB, facilitating the construction of automated testing systems.

 

Technical Specifications

 

Accuracy Class 0.02
Measurement Phase Three-phase
Voltage Measurement Measurement Range: 0V-100V
Accuracy: ±0.02% RG
Current Measurement Measurement Range: 0.3mA-0.3A
Accuracy: ±0.02% RG
Power Factor Measurement Range: -1.0 to 0 to 1.0
Accuracy: 0.0001
Frequency Measurement 45–65Hz
Harmonic Measurement Order 2–50
Measured Power/Energy Voltage 100V, Power Factor 1.0:
>0.1A: 0.02%
>3mA, ≤10mA: 0.04% RG
≥0.3mA, ≤3mA: 0.2% RG
Voltage 100V, Power Factor 0.1:
≥3mA: 0.1% RG

 
Energy Pulse Pulse Output: Frequency <10kHz, TTL level (5V), load capacity ≤5mA
Pulse Input: Frequency <1kHz, TTL level (5V), load capacity <1mA
Annual Stability 60ppm
Environmental Conditions
Power Supply 220V (±10%) AC 50Hz Relative Humidity ≤85%
Operating Temperature 0℃ to 40℃ Storage Conditions -30℃ to 60℃
Dimensions (cm) 43.5 × 48.3 × 17.7
(Width, Depth, Height)
Note: See manual for details

Product Document

File Name

Update Time

Related Products

XL-221 Single-phase Dynamic Distortion Standard Power Source


The XL-221 single-phase dynamic distortion standard power source can output single-phase AC/DC voltage and single-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, as well as superimpose harmonics up to the 100th order, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

XL-3203 Three-Phase Harmonic Standard Power Source


The XL-3203 three-phase harmonic standard power source can be used as a dynamic/harmonic standard voltage source, dynamic/harmonic standard current source, dynamic/harmonic standard power source, AC/DC standard power source, and power quality test standard source. Single/three-phase output options are available, voltage output DC-5KHz, current output 0-2.5KHz, accuracy level 0.1/0.05.

XL-3213 Three-Phase Dynamic Distortion Standard Power Source


The XL-3213 three-phase dynamic distortion standard power source (hereinafter referred to as XL-3213) can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, superimposed harmonics, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

XL-803R Three-Phase Multifunction Standard Meter


The XL803R three-phase multifunction standard meter can simultaneously measure parameters such as three-phase voltage, current, frequency, phase, active power, reactive power, apparent power, and can also measure waveform distortion and harmonics from 2nd to 50th order.

XL-3200T6 AC Electric Energy Meter Dynamic Performance Testing Device


The XL-3200T6 dynamic table calibration device can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, various harmonic superpositions, fundamental wave superimposed with low-frequency oscillation, and custom waveforms.

XL-3223 Three-Phase Dynamic Waveform Standard Electric Energy Meter


XL-3223 Three-phase dynamic waveform standard electric energy meter series products can be used as AC standard meters and harmonic standard meters. Single/three-phase measurement is optional, harmonic measurement range is 2-50 times, accuracy level is 0.05, and harmonic accuracy is 0.2 level.

XL-3203A Three-Phase Harmonic Standard Power Source


The XL-3203A three-phase harmonic standard power source (hereinafter referred to as XL-3203A) can output single-phase AC and DC current. The current output can be sine wave, superimposed DC, DC, half-wave, and various harmonic superpositions. The frequency output range is DC-1.2kHz, suitable for occasions requiring complex power waveform signal output.

XL-8083 Small Analog Electric Energy Meter Calibrator


The XL-8083 small analog electric energy meter calibrator is a new generation high-precision measuring instrument using a 32-bit MCU + DSP processor. It can output high-precision voltage small signals with adjustable power frequency (40Hz to 65Hz), phase, and amplitude. It is suitable for power departments, metering departments, quality inspection departments, research institutions, universities, and R&D enterprises for debugging and calibrating digital electric energy meters, as well as debugging and energy calibration of high and low voltage primary and secondary integrated acquisition devices.

XL-901 DC Standard Meter


The XL-901 DC standard meter can be used for the measurement of DC voltage, current accuracy, power, and electric energy. It features a pulse output terminal for easy calibration by metering institutions and a pulse input terminal for detecting electric energy errors in DC energy meters.

XL-801R Dynamic Waveform Standard Electric Energy Meter


The XL-801R dynamic waveform standard electric energy meter series can be used as an AC standard meter and harmonic standard meter, with options for single/three-phase measurement. The harmonic measurement range is from 2nd to 50th order, accuracy class 0.05, and harmonic accuracy class 0.2.

XL-824D AC/DC Standard Power Source


The XL-824D AC/DC standard source can serve as a three-phase AC standard power source, DC standard power source, DC standard voltmeter, and DC standard ammeter. It has an accuracy level of 0.1/0.05 and can be used for testing and calibration of various AC/DC indicating instruments, power frequency and digital instruments, energy meters, and multimeters. It is suitable for power departments, metrology departments, quality inspection departments, research institutions, universities, and enterprises engaged in the production and research of energy meters.

XL-3270 Programmable Wideband Current Source


The XL-3270 Programmable Wideband AC Source (hereinafter referred to as XL-3270) can output single-phase AC and DC current. The current output can be sine wave, superimposed DC, DC, half-wave, and various harmonic superpositions. The frequency output range is DC-1.2kHz, suitable for occasions requiring complex power waveform signal output.

XL901A Series of DC Standard Electric Energy Meters with Dynamic Characteristics


The XL901A DC standard electric energy meter with dynamic characteristics is designed according to the "JJG-842-2017 Electronic DC Meter Verification Regulations" and the "JJGXXXX-20XX DC Standard Electric Energy" (draft for approval).

XL-201 AC/DC Transient Standard Source


The XL-201 AC/DC transient standard source is suitable for transient testing of analog input merging units in intelligent substations (digital substations). The transient source can output transient test waveform signals that comply with the State Grid Corporation enterprise standard: Q/GDW 11015-2013 "Analog Input Merging Unit Testing Specification." It can output transient high current and can be used in scenarios requiring transient performance testing of merging units, transformers, and similar equipment.

XL-833 Table Source Integrated Tester


The XL-833 AC meter source integrated tester series products can be used for AC quantity detection and calibration. They are suitable for power departments, metrology departments, quality inspection departments, research institutions, higher education institutions, as well as enterprises engaged in the production and research of electric energy meters, distribution terminals, electricity management, load control, power quality, reactive power compensation, and other fields.

XL-8234 Four-Phase AC Power Source


The XL-8234 four-phase AC power source is a new generation high-precision standard power source composed of a 1.2G MAC-based DSP, large-scale FPGA, high-speed high-precision DA, and high-fidelity power amplifier. It is suitable for power departments in power systems that require measurement, inspection, and high-precision standard signal sources for electrical measurement, thermal engineering, remote control, and dispatching. It is also suitable for other occasions that require high-precision standard signal sources for measurement and inspection.

XL-804 Multi-channel Small Signal Analog Voltage Source


The XL-804 multi-channel small signal analog voltage source can output 8 channels of small voltage signals, capable of outputting DC, square wave, triangle wave, sine wave, power frequency harmonics from 2nd to 129th order, custom waveforms, and various types of waveform splicing outputs.

Product Inquiry

Our staff will contact you within 24 hours (working days)