XL-3200T6 AC Electric Energy Meter Dynamic Performance Testing Device
The XL-3200T6 dynamic table calibration device can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, various harmonic superpositions, fundamental wave superimposed with low-frequency oscillation, and custom waveforms.
Product Description
Scope of Application
XL-3200T6 AC Energy Meter Dynamic Performance Testing Device Can output three-phase AC/DC voltage and three-phase AC/DC current, with voltage and current outputs including DC, square wave, triangle wave, sine wave, superimposed harmonics of various orders, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions. The -3dB bandwidth can reach 20kHz. It can be used in scenarios requiring complex power waveform signal output, such as dynamic performance testing of energy meters, transformer testing, harmonic analysis, etc.
Main Functions
- DC output;
- DC voltage and current with ripple;
- Square wave output;
- Triangle wave output;
- Power frequency signal output;
- Power frequency superimposed harmonic output up to the 129th order;
- Voltage output from 0.001 to 5kHz;
- Current output from 0.001 to 5kHz;
- Supports single-cycle waveform output and repeated output;
- Supports formula input and waveform generation;
- Supports waveform splicing, allowing up to 50 formula-generated waveforms to be spliced sequentially into one waveform output;
- Equipped with Ethernet interface, capable of converting network port to 485 communication bus port, facilitating easy reading and modification of multifunction meter data, and can read or automatically set communication addresses for each meter position;
- Can perform tests on energy meters including: odd harmonic testing, half-wave rectified waveform testing, square waveform testing, spike waveform testing, pulse waveform testing, multiple zero-crossing current waveform testing, multiple zero-crossing voltage waveform testing, 1-second voltage interruption testing, 1-cycle voltage interruption testing, 50% voltage sag testing, and ground fault testing;
- Can calibrate energy meters with different constants and has constant verification function; energy pulse frequency supports up to 10KHz;
- Supports various barcode inputs.
Technical Features
- The built-in power source of the XL-3200T6 AC energy meter dynamic performance testing device is a new generation high-precision standard power source based on high-speed DSP, large-scale FPGA, high-speed high-precision DA converter, and high-performance power amplifier. It is suitable for testing the metering capability of energy meters under high and low frequency transient waveform output conditions;
- The XL-3200T6 AC energy meter dynamic performance testing device can output AC voltage up to 150V AC, with stability and accuracy both within 0.005%;
- The XL-3200T6 AC energy meter dynamic performance testing device can output AC current up to 30A AC, with stability and accuracy both within 0.005%;
- The XL-3200T6 AC energy meter dynamic performance testing device has powerful harmonic output performance, with voltage and current able to output harmonics up to the 129th order at power frequency, -3dB bandwidth up to 20KHz, capable of simulating various dynamic performance waveforms of energy meters in practical applications;
- The XL-3200T6 AC energy meter dynamic performance testing device is suitable for performance testing of dynamic energy meters.
- The XL-3200T6 AC energy meter dynamic performance testing device provides formula editing output, supporting addition, subtraction, multiplication, and division operations of trigonometric functions for waveform output.
- The XL-3200T6 AC energy meter dynamic performance testing device supports comtrade waveform recording and playback function, allowing easy reproduction of field signals.
Technical Specifications
Three-phase voltage output | Frequency accuracy | ||||
Name | Specification Range | Remarks | Frequency accuracy of the lowest output phase: 2ppm, other phases accuracy as per the table below: | ||
AC output range | 0-150V DC | Customizable | Frequency | Voltage (accuracy Hz) | Current (accuracy Hz) |
AC frequency range | 0.001-5KHz | 0.001~60Hz | 0.00001 | 0.005 | |
Harmonic output range | 2-129th order | 60~100Hz | 0.02 | 0.02 | |
Voltage output accuracy | Better than 0.05% | 100~1000Hz | 0.5 | 0.5 | |
Harmonic output accuracy | Better than 0.05% | 1000~2000Hz | 5 | 5 | |
Stability | Better than 0.01% | 1000~5000Hz | 50 | 50 | |
Single-phase power | 30VA | Harmonic waveform distortion | |||
Port voltage value | 150VAC | Name | Voltage | Current | |
AC voltage output ranges | 50V, 150V | AC 50Hz | Better than 0.1% | Better than 0.1% | |
Annual stability | 60ppm/year | Note: Waveform distortion is measured at the limit value of each range. When the output is less than the limit value of the range, the waveform distortion will increase. | |||
Note: To ensure output accuracy, the output current must be kept within the limit; otherwise, the accuracy may not meet the required specifications. | Harmonic content rate | ||||
Content rate (fundamental wave 50Hz) | Voltage | Current | |||
Three-phase current output | 10% | Better than 0.05% | Better than 0.05% | ||
Name | Specification Range | Remarks | 50% | Better than 0.05% | Better than 0.05% |
AC output range | 0-30AVC | Customizable | 100% | Better than 0.05% | Better than 0.05% |
AC frequency range | 0.001-5KHz | Load regulation rate | |||
Harmonic output range | 2-129th order | Item (full load) | Specification Range | ||
Current output accuracy | Better than 0.05% | AC voltage output | Better than 0.05% | ||
Harmonic output accuracy | Better than 0.1% | DC voltage output | Better than 0.05% | ||
Stability | Better than 0.05% | AC current output | Better than 0.05% | ||
Single-phase power | 30W | DC current output | Better than 0.05% | ||
Output port voltage value | 3V | Other parameters | |||
AC current output range | 0.01, 0.02, 0.2, 2, 10, 30 (A) | Operating voltage | AC 220V±5% 50Hz | ||
Annual stability | 60ppm/year | Preheating time | <15 minutes | ||
Operating temperature | -10℃ to 55℃ | ||||
Relative humidity | ≤85% no corrosive gases | ||||
Dimensions | Cabinet 600mm×800mm×1610mm (W×D×H) | ||||
Table body 1550mm×540mm×1505mm (L×W×H) |
Product Document
File Name
Update Time
Related Products
XL-221 Single-phase Dynamic Distortion Standard Power Source
XL-3203 Three-Phase Harmonic Standard Power Source
XL-3213 Three-Phase Dynamic Distortion Standard Power Source
XL-803R Three-Phase Multifunction Standard Meter
XL-3003DZ-D Small Current Low Power Factor Standard Electric Energy Meter
XL-3223 Three-Phase Dynamic Waveform Standard Electric Energy Meter
XL-3203A Three-Phase Harmonic Standard Power Source
Product Inquiry