XL-3223 Three-Phase Dynamic Waveform Standard Electric Energy Meter

XL-3223 Three-phase dynamic waveform standard electric energy meter series products can be used as AC standard meters and harmonic standard meters. Single/three-phase measurement is optional, harmonic measurement range is 2-50 times, accuracy level is 0.05, and harmonic accuracy is 0.2 level.

Product Description

Product Introduction

 

XL-3223 Three-Phase Dynamic Waveform Standard Electric Energy Meter Series Products Can be used as AC standard meter, harmonic standard meter, single/three-phase measurement optional, harmonic measurement range 2-50 times, accuracy level 0.05, harmonic accuracy 0.2, suitable for dynamic performance testing and calibration of AC voltage source, AC current source, AC power source, dynamic/harmonic voltage source, dynamic/harmonic current source, dynamic harmonic power source, harmonic electric energy meter, AC electric energy meter. Applicable to power departments, metrology departments, quality inspection departments, scientific research institutions, universities, and enterprises engaged in production and research of electric energy meters, distribution terminals, power management, load control, power quality, reactive power compensation, etc.

 

Main Functions

  • High Measurement Accuracy: Power and energy measurement accuracy level 0.05 level Voltage and current measurement accuracy level 0.05, can be used for metering and calibration of AC quantities, harmonics, and dynamic performance.
  • Wide Measurement Range: Measurement Range 30-420V, 50mA-120A Meets the traceability and calibration requirements of dynamic performance of AC electric energy meters, harmonic electric energy meters, and AC meters.
  • Automatic Range Switching, High Integration: Voltage 30-420V uses a pair of terminal inputs, current 50mA-120A uses a pair of input terminals, full range automatic range switching ensures accuracy indicators of the measurement range.
  • Synchronous Sampling of Voltage and Current: Voltage and current use synchronous sampling technology, under the control of a synchronous clock, sampling voltage and current values at the same moment, calculating power and energy by dot product method, eliminating metering errors caused by asynchronous sampling of voltage and current, improving the accuracy of energy metering.
  • 2~50 Harmonic Measurement Harmonic Measurement Accuracy 0.2% Meets current JJG 1106-2015, AC dynamic performance, IR46 test requirements.
  • 24-bit High-speed ADC: Uses industry-leading 24-bit ADC chip and multi-core DSP processor + DDR large capacity memory, high sampling rate, strong computing power, high accuracy.
  • High Annual Stability Uses high-precision imported components, typical annual measurement stability value is 100 PPM/year Can be used for years without calibration.
  • Measurement Value Statistical Analysis: Can statistically analyze amplitude, power values, minimum value, variation, standard deviation, helping analyze short-term stability and change trends.
  • Human-Machine Interaction: Equipped with large-size touch display screen Clear and intuitive value display, equipped with RJ45, RS232, USB interfaces, convenient for building automatic test systems.

 

Technical Specifications

 

Item XL801R XL-3223
Accuracy Level Power/Energy: 0.1/0.05 level, AC/DC: 0.1/0.05 level, Harmonics: (10%RD + 0.1%RG)
Measurement Phase Single Phase Three Phase
Voltage Measurement Measurement Range: 30-420V
Accuracy: 0.1/0.05%RD (30V~420V), 0.1/0.05%RG (0V~420V)
Current Measurement Measurement Range: 50mA -120A
Accuracy: 0.1/0.05%RD (0.05A~100A), 0.1/0.05%RG (0A~100A)
Power and Energy Measurement Range: Combination of voltage and current measurement ranges
Accuracy: Active: 0.1/0.05%RD PF≥0.5 (0.05A~100A /30V~420V)
Reactive: 0.2/0.1%RD PF≥0.5 (0.05A~100A /30V~420V)
Harmonic Energy Accuracy: 0.5/0.2%
Harmonic Measurement Range: 2~50 harmonics, Accuracy: 0.2/0.1%
Phase Measurement Range: 0~359.99 degrees, Accuracy: 0.1°/0.05° (Current≥200mA, Voltage≥30V)
Frequency Measurement Range: 45Hz~65Hz, Accuracy: 0.005Hz
Power Factor Measurement Range: -1~0~+1, Accuracy: 0.001/0.0005
Energy Pulse Pulse Output: Frequency <10KHz, TTL level (5V), load capacity ≤5mA
Pulse Input: Pulse frequency <1KHz, TTL level (5V), load capacity <1mA
Annual Stability Level 0.1: Voltage, Current: ±200PPM/year
Level 0.05: Voltage, Current: ±100PPM/year

Product Document

File Name

Update Time

Related Products

XL-221 Single-phase Dynamic Distortion Standard Power Source


The XL-221 single-phase dynamic distortion standard power source can output single-phase AC/DC voltage and single-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, as well as superimpose harmonics up to the 100th order, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

XL-3203 Three-Phase Harmonic Standard Power Source


The XL-3203 three-phase harmonic standard power source can be used as a dynamic/harmonic standard voltage source, dynamic/harmonic standard current source, dynamic/harmonic standard power source, AC/DC standard power source, and power quality test standard source. Single/three-phase output options are available, voltage output DC-5KHz, current output 0-2.5KHz, accuracy level 0.1/0.05.

XL-3213 Three-Phase Dynamic Distortion Standard Power Source


The XL-3213 three-phase dynamic distortion standard power source (hereinafter referred to as XL-3213) can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, superimposed harmonics, fundamental wave with low-frequency oscillation, custom waveforms, and various types of waveform splicing output functions.

XL-803R Three-Phase Multifunction Standard Meter


The XL803R three-phase multifunction standard meter can simultaneously measure parameters such as three-phase voltage, current, frequency, phase, active power, reactive power, apparent power, and can also measure waveform distortion and harmonics from 2nd to 50th order.

XL-3003DZ-D Small Current Low Power Factor Standard Electric Energy Meter


The XL-3003DZ-D small current low power factor standard electric energy meter is suitable for power departments, enterprises, and research institutions in the power system that need to measure and verify the metering performance of small current low power factor. It is also suitable for other occasions requiring measurement and verification with a high-precision standard meter for small current low power factor. This device features high safety, ease of operation, a large touchscreen for control and display, and remote control capabilities.

XL-3200T6 AC Electric Energy Meter Dynamic Performance Testing Device


The XL-3200T6 dynamic table calibration device can output three-phase AC/DC voltage and three-phase AC/DC current. Both voltage and current can output DC, square wave, triangle wave, sine wave, various harmonic superpositions, fundamental wave superimposed with low-frequency oscillation, and custom waveforms.

XL-3203A Three-Phase Harmonic Standard Power Source


The XL-3203A three-phase harmonic standard power source (hereinafter referred to as XL-3203A) can output single-phase AC and DC current. The current output can be sine wave, superimposed DC, DC, half-wave, and various harmonic superpositions. The frequency output range is DC-1.2kHz, suitable for occasions requiring complex power waveform signal output.

Product Inquiry

Our staff will contact you within 24 hours (working days)