XL-8093I Network Configuration AC Sensor Calibrator
The XL-8093I network distribution AC sensor calibrator (current) has a self-accuracy of 0.05 level and can calibrate current sensors with small signal output types of 0.2 level and below. It features a portable design, convenient for laboratory and field testing.
Product Description
Product Introduction
XL-8093I Network Access AC Sensor Calibrator (Current) Accuracy level 0.05, capable of calibrating current sensors with small signal output of level 0.2 and below. Portable design for convenient laboratory and field testing.
Main Functions
- Implement calibration of ratio error and phase error of distribution network current sensors;
- Display current primary conductor current, frequency and other related information for comprehensive evaluation of calibrated parameters;
- System reference standard: "T/JDG 018-2018 Technical Conditions for 10kV and 20kV AC Sensors in Distribution Network";
- Real-time display of the waveform of the sensor under test to monitor waveform distortion of the tested transformer;
- Convenient recording of calibration point errors, click to generate report to save recorded error data for archiving or error analysis;
- Portable design, small size and light weight, convenient for testing work, simple and easy wiring;
- Strong adaptability and scalability, supports subsequent upgrades.
Technical Specifications
1. Calibrator Technical Specifications | |
Standard current input range | 50mA, 100mA, 1A, 5A |
Accuracy measurement range | 10mA ~ 6A 0.05%RD |
Ratio error | 0.05%RD |
Phase error | 2′ (> 10mA) |
Input impedance | 0.7Ω@≤100mA, 0.1Ω@≤6A |
2. Small signal transformer input voltage (tested transformer) | |
Small signal transformer input voltage range | 0~7V |
Output accuracy | 0.05%RD (200mV~7V) |
Tested small signal input impedance | 200MΩ |
3. Other specifications | |
Operating power supply voltage range | AC 220V±5% 50Hz |
Power consumption | About 30VA |
Operating temperature | -10℃~50℃ |
Relative humidity | ≤85% Non-corrosive gas |
Dimensions (L×W×H) | 488mm×268mm×199mm |
Total weight | About 8kg |
Product Document
File Name
Update Time
Related Products
XL-809RED Three-Phase Digital Comparative Transformer Calibrator
XL-809E Digital Comparison Transformer Calibrator
XL-809 Electronic Transformer Calibrator
XL-807H Power Frequency Harmonic Current Transformer Calibrator
XL-809RM Three-Phase AC Sensor Calibrator
XL-809RE Three-Phase AC Sensor Calibrator
XL-8093U Network Configuration AC Sensor Calibrator
XL-809R Network Configuration AC Sensor Calibrator
XL-3270 Programmable Wideband Current Source
Product Inquiry