XL-809R Network Configuration AC Sensor Calibrator
The XL-809R network configuration AC sensor calibration instrument is suitable for laboratory and on-site accuracy calibration of electronic transformers with small signal output that comply with IEC60044-7/8 standards. It can perform calibration of electronic transformers with small signal output types of 0.2S grade and below.
Product Description
Product Introduction
XL-809R Distribution Network AC Sensor Calibration Instrument Suitable for laboratory and field accuracy calibration of electronic transformers with small signal output that comply with IEC60044-7/8 standards. The XL-809R distribution network AC sensor calibration instrument has an intrinsic accuracy of 0.05 class and can calibrate electronic transformers with small signal output types of 0.2S class and below.
This calibration instrument features a simple and elegant overall design, an extra-large touchscreen display, supports Ethernet communication via network port, and USB port for data reading and exporting.
Main Features
- Realizes calibration of electronic transformers' ratio error and phase error ;
- Displays relevant information such as voltage, current, and frequency of the primary conductor, facilitating comprehensive evaluation of the calibrated parameters;
- System reference protocols include IEC60044-7/8, JJG313-2010, JJG314-2010;
- Can display the output waveform of the calibrated transformer and related parameters in real time, and automatically save calibration data;
- Convenient recording of verification point errors; clicking to generate reports saves the recorded error data for easy archiving or error analysis;
- Portable design, small size and light weight, convenient for inspection work, supports both touchscreen and keyboard input, providing good usability;
- This product has strong adaptability and scalability, supporting future upgrades;
- Supports input of high-precision standard small signals from 0 to 8V;
Technical Specifications
1. Applicable Protocols | |
Protocols | IEC60044-7/8 |
2. Input Voltage | |
Voltage Measurement Ranges | 20V, 100V |
Voltage Measurement Accuracy | (20~120V) 0.05%RD |
ratio error | 0.05%RD |
phase error | 2' (> 20V) |
Input Impedance | 130KΩ |
3. Input Current | |
Current Measurement Ranges | 200mA, 1A, 5A, 10A |
Accurate Measurement Range | 50mA ~ 10A 0.05%RD |
ratio error | 0.05%RD |
phase error | 2' (> 10mA) |
Input Impedance | 0.7Ω @ ≤100mA, 0.1Ω @ ≤6A |
4. Small Signal Transformer Input Voltage (Tested Transformer) | |
Small Signal Transformer Input Voltage Range | 0~8.0V (50mV, 250mV, 1V, 6.25V) |
ratio error | 0.05%RD |
phase error | 2' (> 22.5mV) |
Input Impedance | 200MΩ @ 0.6nF |
5. Frequency Measurement | |
Frequency Measurement Range | 45Hz~65Hz |
Frequency Measurement Resolution | 0.001Hz |
Frequency Measurement Accuracy | 0.002Hz |
6. Other Specifications | |
Operating Power Supply Voltage Range | AC 220V±5% 50Hz |
Power Consumption | About 30VA |
Warm-up Time | <15 minutes |
Operating Temperature | 0℃~50℃ |
Relative Humidity | ≤85% No corrosive gases |
Dimensions (L×W×H) | 441mm×310mm×177mm |
Overall Weight | 9.25kg |
Product Document
File Name
Update Time
Related Products
XL-809RED Three-Phase Digital Comparative Transformer Calibrator
XL-809E Digital Comparison Transformer Calibrator
XL-809 Electronic Transformer Calibrator
XL-807H Power Frequency Harmonic Current Transformer Calibrator
XL-809RM Three-Phase AC Sensor Calibrator
XL-809RE Three-Phase AC Sensor Calibrator
XL-8093I Network Configuration AC Sensor Calibrator
XL-8093U Network Configuration AC Sensor Calibrator
XL-3270 Programmable Wideband Current Source
Product Inquiry