XL-8093U Network Configuration AC Sensor Calibrator
The XL-8093 distribution network AC sensor calibrator has an inherent accuracy of 0.05 level and can calibrate voltage sensors with small signal output types of 0.2 level and below.
Product Description
Product Introduction
XL-8093U Distribution Network AC Sensor Calibration Instrument The core adopts a dual-CPU architecture with powerful functions, greatly expanding bandwidth with a 24Bit AD chip and 512 times oversampling technology, improving measurement accuracy. At the same time, multi-gear automatic switching and FIR filters are used to enhance dynamic range and signal-to-noise ratio. The operating software features a beautiful interface and is easy to use. The power supply and sampling input adopt extensive electromagnetic compatibility measures, capable of adapting to complex field testing environments. The portable design scheme facilitates laboratory and field testing. The XL-8093 distribution network AC sensor calibration instrument has an accuracy level of 0.05, capable of calibrating voltage sensors with small signal output types of level 0.2 and below.
Main Functions
- Calibrate the ratio error and phase error of distribution network voltage sensors (EVT);
- Display relevant information such as voltage and frequency of the current primary conductor to facilitate comprehensive evaluation of the calibrated parameters;
- System reference standard: "T/JDG 018-2018 Technical Conditions for 10kV and 20kV AC Sensors in Distribution Networks";
- Real-time display of the waveform of the sensor under calibration to monitor waveform distortion of the tested transformer;
- Convenient recording of calibration point errors; clicking report generation saves the recorded error data for easy archiving or error analysis;
- Portable design, small size and light weight, convenient for testing work, simple and convenient wiring;
- This product has strong adaptability and scalability, supporting subsequent upgrades.
Technical Specifications
1. Calibration Instrument Technical Specifications | |
Standard Voltage Input Range | 0~120V |
Standard Voltage Measurement Range | 20V~120V 0.05%RD 1V~20V 0.1%RD |
Calibration Instrument Accuracy Level | Level 0.05 (ratio error better than 0.05%, phase error better than 2′) |
2. Small Signal Transformer Input Voltage (Tested Transformer) | |
Small Signal Transformer Input Voltage Range | 0~7V |
Output Accuracy | 0.05%RD (200mV~7V) |
Input Impedance of Tested Small Signal | 200MΩ |
3. Other Specifications | |
Operating Power Supply Voltage Range | AC 220V±5% 50Hz |
Power Consumption | About 30VA |
Operating Temperature | -10℃~50℃ |
Relative Humidity | ≤85% No corrosive gases |
Dimensions (L×W×H) | 488mm×268mm×199mm |
Total Weight | About 8kg |
Product Document
File Name
Update Time
Related Products
XL-809RED Three-Phase Digital Comparative Transformer Calibrator
XL-809E Digital Comparison Transformer Calibrator
XL-809 Electronic Transformer Calibrator
XL-807H Power Frequency Harmonic Current Transformer Calibrator
XL-809RM Three-Phase AC Sensor Calibrator
XL-809RE Three-Phase AC Sensor Calibrator
XL-8093I Network Configuration AC Sensor Calibrator
XL-809R Network Configuration AC Sensor Calibrator
XL-3270 Programmable Wideband Current Source
Product Inquiry