The XL-9000 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy level better than 0.05%; 0 to 10V DC voltage simulated shunt output with an accuracy level of 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source.
Product Description
Product Introduction
XL-9000 DC Energy Meter Calibration Device Designed to meet the current market demand for DC energy meter calibration, following national standards for DC energy meters, using the latest technology. The main components are imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy better than 0.05%; 0 to 10V DC voltage simulated shunt output with 0.05% accuracy, and supports voltage and current output ripple superposition function. It can be used for virtual load calibration of DC energy meters, ripple interference tests, or as a standalone voltage standard source.
Main Functions
Main Functions | Function Description |
DC Voltage Output | Supports 0~1000V DC voltage output with accuracy better than 0.02% |
Small Signal Output | Supports 0~10V DC voltage output with accuracy better than 0.03% |
Ripple Output | Supports 20~500Hz ripple output |
DC Energy Meter Calibration | Supports virtual load calibration for indirect DC energy meters |
Error Calculation | Supports manual and automatic calibration modes |
Starting Test | Supported |
Creep Test | Supported |
Ripple Test | Supported |
Report Generation | Automatically generates reports based on templates |
Technical Specifications
Name | Specification Range |
Accuracy Class | Class 0.05 |
Voltage and Small Signal Amplitude Accuracy | Voltage: 0.012%RD±0.008%RG (or 10uV) |
Small Signal: 0.02%RD ±0.01%RG (or 2uV) | |
Energy Error | <0.05% |
Number of Output Phases | Single-phase Voltage |
One Small Signal Channel | |
Range Settings | Voltage: 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V |
Small Signal: 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V | |
Output Stability | Voltage: Full scale better than 0.01% ±1uV, typical 0.01% ±0.6uV |
Small Signal: Full scale better than 0.01% ±1uV, | |
Typical 0.01% ±0.6uV | |
Output Power | Voltage: 200 |
10 | |
U≤10 V: ≤ 10 mA; | |
Small Signal: ≤ 10mA; | |
Ripple Superposition | Frequency: 20~500Hz |
Ripple Coefficient: Voltage: <20%, Small Signal: <30% | |
Ripple Voltage Accuracy: 20-50Hz: <1% | |
50-500Hz: <5% | |
Ripple Small Signal Accuracy: 20-500Hz: <1% | |
Long-term Stability | Voltage: ±100PPM/year |
Other Parameters | |
Name | Technical Specifications |
Operating Voltage | AC 220V±5% 50Hz |
Operating Temperature | -5℃ to 40℃ Relative Humidity: ≤90% |
Storage Temperature | -25℃ to 75℃ |
Total Weight | 8.2kg |
Overall Dimensions | 450mm×300mm×200mm |
Cooling Method | Air Cooling |
Noise | <60d |
Product Document
File Name
Update Time
Related Products
XL-9010 Programmable DC Standard Source
XL-9600 DC Standard Source (DC Energy Meter Calibration Device) Series
XL-9100 DC Electric Energy Meter Calibration Device
XL-9020 DC Standard Power Source
XL-9200 DC Energy Meter Calibration Device
XL-9060 DC Electric Energy Meter Calibration Device
Product Inquiry