XL-9010 Programmable DC Standard Source

The XL-9010 programmable DC standard source can output high-precision DC voltage and current signals with a very low ripple factor, making it a highly accurate adjustable voltage and current standard source.

Product Description

Product Introduction

XL-9010 Programmable DC Standard Source Built on 1.2G MAC DSP, large-scale FPGA, high-speed high-precision DA, and high-fidelity power amplifier. Suitable for power systems and measurement and inspection scenarios requiring high-precision standard signal sources. It can output high-precision DC voltage and current signals with ripple coefficient ≤0.1%, typical output stability of 0.004% RD, especially suitable for calibration of transmitters and various high-precision DC devices in the power sector.

 

Main Functions  

  • Can output pure standard DC power signals with ripple content of 0.1% (typical value).
  • Transmitter Calibration: Can simulate output of small DC voltage and current signals for transmitter calibration.
  • Communication Function: Used for communication with PC and other master control modules, communication protocol is "Programmable Power Supply Interface Protocol".
  • Excellent temperature stability, core components are military-grade products with temperature coefficient as low as 1PPM, ensuring output accuracy in outdoor temperature environments.
  • Can be conveniently connected to PC via an RS232 port to expand other functions.
  • Secondary Development: Users can develop various required functions and automation software through the communication port based on the "Programmable Power Supply Interface Protocol".
  • Configuration Software: Equipped with upper computer configuration software, allowing easy control on industrial control computers once the device power is turned on. Users can also install the configuration software on a computer and operate via RS232 communication cable.
  • Local Function: Equipped with 800*600 large touchscreen LCD and industrial control computer operation, facilitating local operation, software upgrades, and data transfer.

 

Technical Specifications

DC Voltage Output
Adjustment Fineness 0.01% RG
Accuracy Better than ±0.05% RG
Resolution 1mV
Stability Better than ±0.01% RG/1min
Output Power Rated 5W
Full Load Adjustment Time Less than 1mS
Output Range 0V~24V
Ripple Content Less than 0.1%
Temperature Drift ±8PPM/℃
Long-term Stability 60PPM/year
DC Current Output
Adjustment Fineness 0.01% RG
Accuracy Better than ±0.05% RG
Stability Better than ±0.01% RG/1min
Resolution 1uA
Output Power Rated 0.2W
Full Load Adjustment Time Less than 1mS
Output Range Current 0~20mA
Ripple Content Less than 0.1%
Temperature Drift ±8PPM/℃
Long-term Stability 60PPM/year
    Operating Power Supply
Operating Power Supply 220V (±5%) AC @50Hz
    Environmental Conditions
Operating Temperature 0℃~40℃
Relative Humidity ≤85%
Storage Conditions -30℃~60℃

Product Document

File Name

Update Time

Related Products

XL-9600 DC Standard Source (DC Energy Meter Calibration Device) Series


The XL-9600 DC Standard Source (DC Energy Meter Calibration Device) series can be used as a standard voltage source, standard current source, standard low-signal voltage source, direct or indirect standard power source, and standard energy meter calibration device.

XL-9100 DC Electric Energy Meter Calibration Device


This device uses an 800×600 LCD screen, featuring a clear and simple interface, easy operation, and good visual effects. The waveform quantization employs 32-bit dual modulation output technology to ensure high precision output.

XL-9020 DC Standard Power Source


The XL-9020 DC standard power source is designed to meet the current market demand for DC energy meter calibration. It complies with the national standards for DC energy meters and uses the latest technology. The main components are imported industrial-grade devices. It supports DC current output from 0 to 20ADC (MAX: 24A), DC voltage output from 0 to 1000V, and 0 to 10V DC voltage analog shunt output. The energy accuracy level is better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source, current standard source, or power standard source.

XL-9200 DC Energy Meter Calibration Device


The XL-9200 DC energy meter calibration device, based on the "JJG-842-2017 Electronic DC Meter Calibration Regulations" and "GBT 33708-2017 Static DC Energy Meter" (co-drafted by Xinglong Technology), can serve as a standard voltage source, standard current source, standard small signal voltage source, direct or indirect standard power source, and standard energy meter calibration device. It meets the output requirements for DC voltage, current, small signal voltage amplitude, power, and energy, with accuracy levels of 0.05/0.02 for voltage and current, and 0.1/0.05 for energy. It can be used for DC testing, traceability, and calibration, suitable for regional metrology centers, provincial metrology centers, research institutions, energy meter manufacturers, and enterprises related to DC metrology. Utilizing the latest technology, its main components are all imported industrial-grade devices. It supports large current signals up to 0–250 ADC with an accuracy better than 0.03%; DC voltage output up to 0–1000 V with an accuracy better than 0.02%; 0–5 V DC voltage analog shunt output with an accuracy of 0.03%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration and ripple interference testing of DC energy meters.

XL-9060 DC Electric Energy Meter Calibration Device


The XL-9060 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC current output from 0 to 60ADC, DC voltage output from 0 to 1000V, and 0 to 5V DC voltage simulated shunt output, with an accuracy level better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference tests, or as standalone voltage standard source, current standard source, and power standard source.

XL-9000 DC Electric Energy Meter Calibration Device


The XL-9000 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy level better than 0.05%; 0 to 10V DC voltage simulated shunt output with an accuracy level of 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source.

Product Inquiry

Our staff will contact you within 24 hours (working days)