The XL-9020 DC standard power source is designed to meet the current market demand for DC energy meter calibration. It complies with the national standards for DC energy meters and uses the latest technology. The main components are imported industrial-grade devices. It supports DC current output from 0 to 20ADC (MAX: 24A), DC voltage output from 0 to 1000V, and 0 to 10V DC voltage analog shunt output. The energy accuracy level is better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source, current standard source, or power standard source.

Product Description

Product Introduction

XL-9020 DC Energy Meter Calibration Device Independently developed by our company, strictly following national standards, using cutting-edge technology and internationally advanced industrial-grade core components. This device provides 0~20A DC (maximum 24A) direct current, 0~1000V DC (maximum 1150V) direct voltage and 0~10V DC small signal output (used to simulate shunt), its energy measurement accuracy is better than 0.05% . The device supports voltage and current output superimposed ripple and is suitable for DC energy meter virtual load calibration and ripple influence testing , also can be used as an independent high-precision standard voltage source, current source, or power source usage. Equipped with high-resolution touch LCD screen , the interface is simple and intuitive, easy to operate; using 32-bit dual modulation output technology to ensure accuracy, all outputs have overload and overheat protection , ensuring operation is safe and reliable

 

Main Functions

 

Main Functions Function Description
DC Voltage Output Supports 0~1000V DC voltage output, accuracy: <0.02%
DC Current Output Supports 0~24A DC current output, accuracy: <0.02%
Small Signal Output Supports 0~10V DC voltage output, accuracy: <0.03%
Error Calculation Supports manual calibration and automatic calibration modes
Start-up Test Supports
Creep Test Supports
Ripple Test Supports
Generate Reports Can automatically generate reports based on templates

 

Technical Specifications
 

No. Name Specification Range
1 Energy Accuracy Class Class 0.05
2 Voltage Amplitude Accuracy 0.012%RD±0.008%RG (or 10uV)
3 Current Amplitude Accuracy 0.012%RD ±0.008%RG (or 1uA)
4 Small Signal Amplitude Accuracy 0.02%RD ±0.01%RG (or 2uV)
5 Energy Error <0.05%
6 Number of Output Phases 1 phase voltage, 1 phase current, 1 small signal channel
7 Range Settings Voltage: 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V;
Current: 1mA, 3mA, 10mA, 30mA, 100mA, 0.3A, 1A, 3A, 10A, 20A;
Small Signal: 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V.
8 Output Stability (/min) Voltage: full scale better than 0.01%, typical value 0.005%;
Current: full scale better than 0.002%;
Small Signal: full scale better than 0.01% ±1uV,
typical value 0.01% ±0.6uV.
9 Output Power Current: <40VA, port voltage: <2V;
Voltage: 200

10 200 V : ≤ 100mA

U 10 V : ≤ 10 mA
Small Signal: ≤10mA.
10 Long-term Stability Voltage, Current: ±100PPM/year
11 Ripple Superimposition Frequency: 20~500Hz;
Ripple Voltage Accuracy: 20-50Hz: <1%;
50-500Hz: <5%,
Ripple small signal accuracy: 20-500Hz: <1%
  Other parameters
Technical Specifications Technical Specifications
Operating voltage AC 220V±5% 50Hz
Operating temperature -5℃ to 40℃ Relative humidity: ≤80%RH
Storage temperature -25℃ to 75℃
Total weight About 35kg
Overall dimensions 524mm×590mm×231mm
Cooling method Air cooling
Noise <60dB

Product Document

File Name

Update Time

Related Products

XL-9010 Programmable DC Standard Source


The XL-9010 programmable DC standard source can output high-precision DC voltage and current signals with a very low ripple factor, making it a highly accurate adjustable voltage and current standard source.

XL-9600 DC Standard Source (DC Energy Meter Calibration Device) Series


The XL-9600 DC Standard Source (DC Energy Meter Calibration Device) series can be used as a standard voltage source, standard current source, standard low-signal voltage source, direct or indirect standard power source, and standard energy meter calibration device.

XL-9100 DC Electric Energy Meter Calibration Device


This device uses an 800×600 LCD screen, featuring a clear and simple interface, easy operation, and good visual effects. The waveform quantization employs 32-bit dual modulation output technology to ensure high precision output.

XL-9200 DC Energy Meter Calibration Device


The XL-9200 DC energy meter calibration device, based on the "JJG-842-2017 Electronic DC Meter Calibration Regulations" and "GBT 33708-2017 Static DC Energy Meter" (co-drafted by Xinglong Technology), can serve as a standard voltage source, standard current source, standard small signal voltage source, direct or indirect standard power source, and standard energy meter calibration device. It meets the output requirements for DC voltage, current, small signal voltage amplitude, power, and energy, with accuracy levels of 0.05/0.02 for voltage and current, and 0.1/0.05 for energy. It can be used for DC testing, traceability, and calibration, suitable for regional metrology centers, provincial metrology centers, research institutions, energy meter manufacturers, and enterprises related to DC metrology. Utilizing the latest technology, its main components are all imported industrial-grade devices. It supports large current signals up to 0–250 ADC with an accuracy better than 0.03%; DC voltage output up to 0–1000 V with an accuracy better than 0.02%; 0–5 V DC voltage analog shunt output with an accuracy of 0.03%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration and ripple interference testing of DC energy meters.

XL-9060 DC Electric Energy Meter Calibration Device


The XL-9060 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC current output from 0 to 60ADC, DC voltage output from 0 to 1000V, and 0 to 5V DC voltage simulated shunt output, with an accuracy level better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference tests, or as standalone voltage standard source, current standard source, and power standard source.

XL-9000 DC Electric Energy Meter Calibration Device


The XL-9000 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy level better than 0.05%; 0 to 10V DC voltage simulated shunt output with an accuracy level of 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source.

Product Inquiry

Our staff will contact you within 24 hours (working days)