XL-9060 DC Electric Energy Meter Calibration Device

The XL-9060 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC current output from 0 to 60ADC, DC voltage output from 0 to 1000V, and 0 to 5V DC voltage simulated shunt output, with an accuracy level better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference tests, or as standalone voltage standard source, current standard source, and power standard source.

Product Description

Product Introduction
 

The XL-9060 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It complies with national standards for DC energy meters and uses the latest technology. The main components are imported industrial-grade parts. It supports DC current output from 0 to 60ADC, DC voltage output from 0 to 1000V (maximum 1150V), and 0 to 5V DC voltage simulated shunt output, with an accuracy level better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference tests, or as a standalone Voltage Standard Source Current Standard Source Power Standard Source Use.

This device is equipped with a high-resolution LCD display with touch functionality. The software interface is designed to be simple and easy to operate, with excellent visual effects. Waveform quantization uses 32-bit dual modulation output technology to ensure high precision output. All outputs have overload and overheat protection functions, ensuring safety and reliability during use.

 

Main Functions                            

 

Main Functions Function Description
DC Voltage Output Supports 0~1000V DC voltage output, accuracy: <0.02%/RG
DC Current Output Supports 0~60A DC current output, accuracy: <0.03%/RG
Small Signal Output Supports 0~5V DC voltage output, accuracy: <0.03%
Error Calculation Supports manual and automatic calibration modes
Start-up Test Supports
Creep Test Supports
Ripple Test Supports
Generate Reports Reports can be automatically generated based on templates

 

Technical Specifications
 

Energy Accuracy Level Level 0.05
Voltage Amplitude Accuracy 0.012%RD ±0.008%RG (or 10uV)
Current Amplitude Accuracy 0.012%RD ±0.008%RG (or 1uA)
Small Signal Amplitude Accuracy 0.02%RD ±0.01%RG (or 2uV)
Energy Error <0.05%
Number of Output Phases 1 phase voltage, 1 phase current, 1 small signal channel
Range Settings Voltage: 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V
Current: 1mA, 3mA, 10mA, 30mA, 100mA, 0.3A, 1A, 3A, 10A, 20A, 60A
Small Signal: 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V
Output Stability (/min) Voltage: Full scale better than 0.01%, typical 0.005%
Current: Full scale better than 0.002%
Small Signal: Full scale better than 0.01% ±1uV, typical 0.01% ±0.6uV
Output Power Current: <120VA, port voltage: <2V
Voltage: 200
Small Signal: ≤ 10mA,
Long-term Stability Voltage, Current: ±100PPM/year
Ripple Superposition Frequency: 20~500Hz
Ripple Voltage Accuracy: 20-50Hz: <1%
50-500Hz: <5%
Ripple Small Signal Accuracy: 20-500Hz: <1%
Other Parameters
Operating Voltage AC 220V±5% 50Hz
Operating Temperature -5℃ to 40℃ Relative Humidity: ≤80%
Storage Temperature -25℃~75℃
Total Weight About 21kg
Overall Dimensions 379mm×590mm×199mm
Cooling Method Air Cooling
Noise <60dB

Product Document

File Name

Update Time

Related Products

XL-9010 Programmable DC Standard Source


The XL-9010 programmable DC standard source can output high-precision DC voltage and current signals with a very low ripple factor, making it a highly accurate adjustable voltage and current standard source.

XL-9600 DC Standard Source (DC Energy Meter Calibration Device) Series


The XL-9600 DC Standard Source (DC Energy Meter Calibration Device) series can be used as a standard voltage source, standard current source, standard low-signal voltage source, direct or indirect standard power source, and standard energy meter calibration device.

XL-9100 DC Electric Energy Meter Calibration Device


This device uses an 800×600 LCD screen, featuring a clear and simple interface, easy operation, and good visual effects. The waveform quantization employs 32-bit dual modulation output technology to ensure high precision output.

XL-9020 DC Standard Power Source


The XL-9020 DC standard power source is designed to meet the current market demand for DC energy meter calibration. It complies with the national standards for DC energy meters and uses the latest technology. The main components are imported industrial-grade devices. It supports DC current output from 0 to 20ADC (MAX: 24A), DC voltage output from 0 to 1000V, and 0 to 10V DC voltage analog shunt output. The energy accuracy level is better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source, current standard source, or power standard source.

XL-9200 DC Energy Meter Calibration Device


The XL-9200 DC energy meter calibration device, based on the "JJG-842-2017 Electronic DC Meter Calibration Regulations" and "GBT 33708-2017 Static DC Energy Meter" (co-drafted by Xinglong Technology), can serve as a standard voltage source, standard current source, standard small signal voltage source, direct or indirect standard power source, and standard energy meter calibration device. It meets the output requirements for DC voltage, current, small signal voltage amplitude, power, and energy, with accuracy levels of 0.05/0.02 for voltage and current, and 0.1/0.05 for energy. It can be used for DC testing, traceability, and calibration, suitable for regional metrology centers, provincial metrology centers, research institutions, energy meter manufacturers, and enterprises related to DC metrology. Utilizing the latest technology, its main components are all imported industrial-grade devices. It supports large current signals up to 0–250 ADC with an accuracy better than 0.03%; DC voltage output up to 0–1000 V with an accuracy better than 0.02%; 0–5 V DC voltage analog shunt output with an accuracy of 0.03%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration and ripple interference testing of DC energy meters.

XL-9000 DC Electric Energy Meter Calibration Device


The XL-9000 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy level better than 0.05%; 0 to 10V DC voltage simulated shunt output with an accuracy level of 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source.

Product Inquiry

Our staff will contact you within 24 hours (working days)