XL-9600 DC Standard Source (DC Energy Meter Calibration Device) Series

The XL-9600 DC Standard Source (DC Energy Meter Calibration Device) series can be used as a standard voltage source, standard current source, standard low-signal voltage source, direct or indirect standard power source, and standard energy meter calibration device.

Product Description

Product Introduction

 

The XL-9600 DC Standard Source (DC Energy Meter Calibration Device) series is based on the "JJG-842-2017 Electronic DC Meter Calibration Regulations" and "GBT 33708-2017 Static DC Energy Meter" (co-drafted by Xinglong Technology). It can serve as a standard voltage source, standard current source, standard small signal voltage source, direct or indirect standard power source, and standard energy meter calibration device. It meets the output requirements for DC voltage, current, small signal voltage amplitude, power, and energy with accuracy levels of 0.05/0.02 (voltage and current) and 0.1/0.05 (energy). It is suitable for DC testing and calibration, applicable to State Grid Metrology Centers, research institutions, energy meter manufacturers, and enterprises related to DC metering.
 

Functional Features
 

  • High Output Accuracy: Power and Energy Output Accuracy Level 0.1/0.05 Level Optional Voltage and Current Output Accuracy Level 0.05/0.02 Level Optional, suitable for DC metering and calibration.
  • Wide Output Range: Output Range 10mV-1150V, 100uA-600A, 100uV-5V Meets the testing and calibration requirements of DC voltmeters, DC ammeters, small signal voltmeters, DC wattmeters, DC energy meters, and other DC metering devices.
  • Automatic Range Switching Across Full Output Range: Voltage, current, and small signal voltage automatically switch to appropriate output ranges throughout the entire output range to ensure accuracy indicators across the full output range.
  • Superimposed Ripple Output: Voltage, current, and small signal voltage can superimpose ripple output with frequencies of 20-500Hz ripple output to calibrate the ripple effect on DC energy meters.
  • Comprehensive Calibration Items: Meets the "JJG-842-2017 Electronic DC Meter Calibration Regulations" requirements for creep test, start-up test, basic error, instrument constant test, and clock daily timing error.
  • High Small Signal Accuracy: Output uses 4-wire feedback output to eliminate the influence of line impedance on small signal output, ensuring small signal output accuracy.
  • High Output Stability: Uses linear power amplifier, typical output stability can reach 0.005%RG/min
  • Auxiliary Power Supply (some models): Built-in 12V, 24V DC, 220V AC three types of auxiliary power outputs and supports ±20% adjustable to meet power supply voltage variation test requirements.
  • High Accuracy Second Pulse: Built-in high accuracy crystal oscillator clock, typical accuracy is 200ns/s convenient for clock testing and calibration.
  • Safe, Reliable, and Flexible Use: Voltage and current (including direct and indirect current) are fully electrically isolated. Accurate measurement can be achieved regardless of whether the measured voltage and current are isolated or whether voltage and current share high or low terminals .
  • Professional Software: Supports automatic or semi-automatic calibration of DC energy meters, supports calibration data recording and management, and can automatically generate calibration certificates according to templates after calibration, with freely editable templates.
  • Human-Machine Interaction, Simple and Flexible: Equipped with a large touch display screen, clear and intuitive value display, and multiple interfaces including RJ45, RS232, and USB, facilitating the construction of automatic test systems.

 

Technical Specifications

 

Item XL-9000 XL-9060 XL-9100 XL-9200 XL-9600
Accuracy Level Power/Energy: 0.1/0.05 level, Voltage/Current/Small Signal: 0.05/0.02 level
Voltage Output Output Range: 10mV-1150V, Output Power: <30W (or <100mA)
Current Output No current output 0.1mA ~72A 0.1mA ~120A 0.1mA ~300A 0.1mA ~600A
Output port voltage < 2V
Small Signal Output Output Range 100uV-5V, Output Power: ≤100mV: <1mA, >100mV: 10mA
Typical Output Stability 0.05 level: Voltage/Current: 0.01%RG/min, Small Signal: 0.02%RG(2uV)/min
0.01 level: Voltage/Current: 0.005%RG/min, Small Signal: 0.01%RG(2uV)/min
Output Power/Electric Energy Range: Combination of voltage and current output ranges
Accuracy: Combination of voltage and current output accuracy
Stability: Combination of voltage and current output stability
Pulse Output Pulse frequency <10KHz, TTL level (5V), load capacity ≤5mA
Pulse Input Pulse frequency <1KHz, TTL level (5V), load capacity <1mA
Ripple Output Frequency: 20~500Hz, Accuracy: 0.5% RG (voltage), 1% RG (current, small signal)
Annual Stability Voltage, Current: ±100PPM/year, Small Signal: ±150PPM/year

Product Document

File Name

Update Time

Related Products

XL-9010 Programmable DC Standard Source


The XL-9010 programmable DC standard source can output high-precision DC voltage and current signals with a very low ripple factor, making it a highly accurate adjustable voltage and current standard source.

XL-9100 DC Electric Energy Meter Calibration Device


This device uses an 800×600 LCD screen, featuring a clear and simple interface, easy operation, and good visual effects. The waveform quantization employs 32-bit dual modulation output technology to ensure high precision output.

XL-9020 DC Standard Power Source


The XL-9020 DC standard power source is designed to meet the current market demand for DC energy meter calibration. It complies with the national standards for DC energy meters and uses the latest technology. The main components are imported industrial-grade devices. It supports DC current output from 0 to 20ADC (MAX: 24A), DC voltage output from 0 to 1000V, and 0 to 10V DC voltage analog shunt output. The energy accuracy level is better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source, current standard source, or power standard source.

XL-9200 DC Energy Meter Calibration Device


The XL-9200 DC energy meter calibration device, based on the "JJG-842-2017 Electronic DC Meter Calibration Regulations" and "GBT 33708-2017 Static DC Energy Meter" (co-drafted by Xinglong Technology), can serve as a standard voltage source, standard current source, standard small signal voltage source, direct or indirect standard power source, and standard energy meter calibration device. It meets the output requirements for DC voltage, current, small signal voltage amplitude, power, and energy, with accuracy levels of 0.05/0.02 for voltage and current, and 0.1/0.05 for energy. It can be used for DC testing, traceability, and calibration, suitable for regional metrology centers, provincial metrology centers, research institutions, energy meter manufacturers, and enterprises related to DC metrology. Utilizing the latest technology, its main components are all imported industrial-grade devices. It supports large current signals up to 0–250 ADC with an accuracy better than 0.03%; DC voltage output up to 0–1000 V with an accuracy better than 0.02%; 0–5 V DC voltage analog shunt output with an accuracy of 0.03%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration and ripple interference testing of DC energy meters.

XL-9060 DC Electric Energy Meter Calibration Device


The XL-9060 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC current output from 0 to 60ADC, DC voltage output from 0 to 1000V, and 0 to 5V DC voltage simulated shunt output, with an accuracy level better than 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference tests, or as standalone voltage standard source, current standard source, and power standard source.

XL-9000 DC Electric Energy Meter Calibration Device


The XL-9000 DC energy meter calibration device is designed to meet the current market demand for DC energy meter calibration. It follows the national standards for DC energy meters and adopts the latest technology. The main components are all imported industrial-grade devices. It supports DC voltage output from 0 to 1000V with an accuracy level better than 0.05%; 0 to 10V DC voltage simulated shunt output with an accuracy level of 0.05%. It also supports voltage and current output ripple superposition functions, which can be used for virtual load calibration of DC energy meters, ripple interference testing, or as a standalone voltage standard source.

Product Inquiry

Our staff will contact you within 24 hours (working days)