XL-9000T16 DC Meter Calibration Device

The XL-9000T16 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output 0 to 1000V (MAX: 1150V) DC voltage and 0 to 5V small signals, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 16 slots, allowing simultaneous calibration of 16 energy meters.

Product Description

Product Introduction

The XL-9000T16 DC Meter Calibration Device is designed to meet the current market demand for DC energy meter calibration. It strictly follows national standards related to DC energy meters and employs cutting-edge technology. Its core components are all selected from internationally advanced industrial-grade devices. The XL-9000T16 includes a voltage source, small signal source, main control unit, and meter mounting platform. It can output 0 to 1000V DC (maximum 1150V) DC voltage, 0 to 5V DC small signal voltage, enabling calibration of indirect DC energy meters with an energy accuracy of 0.05 level. The meter mounting platform is mainly used for meter position fixing, featuring 16 positions, allowing simultaneous calibration of 16 energy meters.

 

Main Functions

 

  • The shell is made of special aluminum alloy material, which is beautiful, sturdy in structure, detachable, and easy to transport.
  • Uses a dedicated junction box for convenient meter calibration.
  • High-quality linear power amplifier with low ripple output and good stability.
  • Multiple protection systems with audible and visual alarm functions for higher reliability.
  • Equipped with 485 communication function, allowing easy reading and modification of data inside multifunction meters, and can read communication addresses of each meter position.
  • The platform has a dedicated meter holder for direct meter mounting. Once the meter is mounted, basic error, daily timing error, and meter pulse constant tests can be automatically completed.
  • Fully automatic inspection of meter start-up, creeping, basic error, and other items according to regulations.
  • Designed completely according to DC energy meter specifications, compatible with calibration and performance testing of various DC meters.
  • Voltage and small signals can respectively superimpose 20 to 500Hz ripple, with adjustable ripple amplitude and phase maintained in phase.
  • Can calibrate energy meters with different constants and has a meter pulse constant test function.
  • Dedicated photoelectric sampler can collect LED light pulse signals from electronic meters.
  • Dedicated pulse sampling interface with high-voltage isolation circuit to prevent high-voltage misconnection.
  • Has the function of power-based meter testing, can directly read the power measurement value of the tested meter through the 485 bus interface and calculate the error.
  • Can display parameters such as power, voltage, current, and ripple.
  • Supports PC connection with dedicated calibration software featuring a user-friendly interface and simple, intuitive calibration settings. Allows manual addition and setting of any calibration points, with data storage and printing capabilities.
  • Equipped with GPS clock reference, supporting daily timing error testing of energy meters.
  • The device uses single-phase power supply for user convenience.
  • Each meter position has automatic and manual switching capabilities, allowing users to select meter positions for calibration easily through software.
  • Equipped with 220VAC, 12VDC, and 24VDC auxiliary power interfaces, adjustable ±20%, enabling power drop tests for energy meters.

 

Technical Specifications

 

Number of Meter Positions
DC Meter Calibration Device Meter Positions 16 positions
DC Voltage Output
Range 0 to 1000V (MAX: 1150V)
Ranges 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V
Accuracy 0.012%RD ±0.008%RG
Allowable Load Current Voltage: 200 < U ≤ 1150 V: ≤ 25 mA;
10 < U ≤ 200 V: ≤ 100 mA;
U ≤ 10 V: ≤ 10 mA.
Indirect Current Output
Range 0 to 5V
Ranges 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 10V
Accuracy 0.02%RD ±0.01%RG (or 2uV)
Load Capacity Small signal: ≤ 10mA
Energy Accuracy
Energy Accuracy Level 0.05%
Output Stability
Voltage Stability Full scale better than 0.01% ±4uV, typical value 0.005% ±2uV
Small Signal Stability Full scale better than 0.01% ±1uV, typical value 0.01% ±0.6uV
Annual Drift Less than 100ppm/year
Voltage Ripple Output Capability
Ripple Frequency 20 to 500Hz
Ripple Coefficient Voltage: <20%, Small signal: <30%
Ripple Phase Voltage ripple phase error less than 0.1 degrees
Ripple Accuracy Ripple voltage accuracy: 20-50Hz: <1%
50-500Hz: <5%
Ripple small signal accuracy: 20-500Hz: <1%
Other indicators
Operating power supply AC 220V±5% 50Hz
Operating temperature -5℃ to 40℃ Relative humidity: ≤90%
Storage temperature -25℃ to 75℃
Relative humidity ≤85% Non-corrosive gases
Dimensions Main unit 2238mm × 670mm × 1688mm (L × W × H)
Computer desk 850mm × 670mm × 722mm (L × W × H)

Product Document

File Name

Update Time

Related Products

XL-9100T6 DC Meter Calibration Device


The XL-9100T6 DC energy meter calibration bench includes a standard source cabinet and an energy meter hanging table body. The cabinet houses the voltage source, small signal source, current source, main control unit, and industrial control computer display unit.

XL-9201 DC Shunt Calibrator


The XL-9201T3 DC shunt calibrator can test shunts of various specifications, featuring functions such as testing the basic error and DC resistance of shunts, plotting I-R and R-t curves, and automatically calculating the power factor. Its measurement accuracy is 0.05 level. This device is equipped with a high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate shunts of various specifications, providing high testing efficiency.

XL-9300T6 DC Energy Meter Calibration Device


The XL-9300T6 includes a voltage source, current source, small signal source, main control unit, and meter mounting platform. It can output 0 to 1000V DC (maximum 1150V) direct current voltage, 0 to 300A DC direct current output, and 0 to 5V DC small signal output. It is capable of calibrating both indirect and direct DC energy meters with an energy accuracy level of 0.05. The meter mounting platform is mainly used for securing meter positions, featuring 6 slots, allowing simultaneous calibration of 6 energy meters.

XL-9600T6 DC Meter Calibration Device


The XL-9600T6 DC meter calibration device includes a standard source cabinet and an electricity meter hanging table body. The cabinet houses a voltage source, a small signal source, a current source, a main control unit, and an industrial control computer display unit. It can output DC voltage from 0 to 1000V (MAX: 1150V), DC current from 0 to 600A, and small signals from 0 to 5V, enabling incremental output for electricity meter calibration. The voltage accuracy is 0.02 level, current accuracy is 0.02 level, and energy accuracy is 0.05 level. The hanging table body is mainly used for meter position fixing, including a meter rack and table body, with six meter positions, capable of simultaneously calibrating 6 electricity meters (0~100A) and 3 electricity meters (0~600A).

XL-9201T6 DC Shunt Calibrator


The XL-9201T6 DC shunt calibrator can test various specifications of shunts according to the JJG1069-2011 DC shunt calibration regulations. It is capable of testing the basic error and DC resistance of shunts, plotting I-R curves and R-t curves, among other functions. Its measurement accuracy level is 0.05. This device is equipped with a built-in high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate various specifications of shunts, providing high testing efficiency.

XL-9100T18 DC Meter Calibration Device


The XL-9100T18 DC energy meter calibration device is equipped with 18 independent voltage sources and 1 current source. It can output DC voltage from 0 to 1500V (MAX: 1725V) and DC current from 0 to 100A, enabling incremental output calibration for direct DC energy meters. The voltage accuracy is 0.02 level, current accuracy is 0.03 level, and energy accuracy is 0.05 level. It features a dedicated meter rack with 18 slots, allowing simultaneous calibration of 18 direct energy meters (0~100A).

XL-9000T8 DC Meter Calibration Device


The XL-9000T8 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output DC voltage from 0 to 1000V (MAX: 1150V) and a small signal of 0 to 5V, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 8 slots, allowing simultaneous calibration of 8 energy meters.