XL-9300T6 DC Energy Meter Calibration Device

The XL-9300T6 includes a voltage source, current source, small signal source, main control unit, and meter mounting platform. It can output 0 to 1000V DC (maximum 1150V) direct current voltage, 0 to 300A DC direct current output, and 0 to 5V DC small signal output. It is capable of calibrating both indirect and direct DC energy meters with an energy accuracy level of 0.05. The meter mounting platform is mainly used for securing meter positions, featuring 6 slots, allowing simultaneous calibration of 6 energy meters.

Product Description

Product Introduction

 

XL-9300T6 DC Energy Meter Calibration Device In response to the current market demand for DC energy meter calibration, strictly following national standards related to DC energy meters and utilizing cutting-edge technology, the core components are all selected from internationally advanced industrial-grade devices. The XL-9300T6 includes a voltage source, current source, small signal source, main control unit, and meter mounting platform. It can output 0 to 1000V DC (maximum 1150V) DC voltage, 0 to 300A DC current output, and 0 to 5V DC small signal voltage output, enabling calibration of both indirect and direct DC energy meters with an energy accuracy of 0.05 class. The meter mounting platform is mainly used for fixing meter positions, featuring 6 slots, allowing simultaneous calibration of 6 energy meters.

 

Main Functions

  1. The product casing is made of special aluminum alloy material, not only elegant in appearance but also sturdy and durable. It adopts a detachable design, greatly facilitating transportation and maintenance.
  2. Equipped with a standard meter mounting base, it can automatically complete tests such as basic error, daily timing error, and pulse constant test immediately after mounting the meter, making the calibration process more convenient and efficient.
  3. Built-in high-performance linear power amplifier effectively suppresses output ripple, ensuring high stability and low noise characteristics of the DC output.
  4. Integrated multiple protection systems with audible and visual alarm functions significantly enhance device reliability and ensure safe use.
  5. Equipped with 485 communication function, it can read electrical parameters of DC energy meters according to the DL/T645 communication protocol, enabling meter constant tests or electrical parameter tests (such as current error, voltage error, power error, etc.).
  6. Capable of fully automatic testing of energy meter start-up test, creeping test, basic error, meter constant test, and clock daily timing error according to DC energy meter calibration procedures, improving testing efficiency.
  7. Features calibration data management function, automatically generating reports based on user templates.
  8. Designed strictly according to JJG 1186-2022 DC energy meter calibration device calibration procedures, compatible with calibration or performance testing of various DC meters, meeting diverse needs.
  9. Can superimpose ripple output of 20 to 500Hz, with adjustable ripple amplitude and phase, meeting ripple influence testing requirements of DC energy meters.
  10. Equipped with optical pulse and electrical pulse sampling functions, accurately capturing LED optical pulse signals or electrical pulse signals of electronic meters. Built-in high-voltage isolation circuit effectively prevents high-voltage misconnection, ensuring device safety.
  11. Real-time display of key parameters such as power, voltage, current, and ripple, facilitating user monitoring of device status.
  12. Integrated GPS clock reference, supporting clock daily timing error testing of energy meters.
  13. The device uses single-phase power supply, convenient for user connection and use, lowering the usage threshold.
  14. Offers both automatic and manual calibration modes, allowing users to flexibly select meter positions based on the meter mounting situation at each slot.
  15. The device can provide 220VAC, 12VDC, and 24VDC auxiliary power outputs, adjustable by ±20%, supporting power drop tests of energy meters, fully meeting testing requirements.

 

Technical Specifications

 

DC Energy Meter Platform Slots
DC Energy Meter Platform Slots 6 slots
Six-channel DC Voltage Output
Range 0 to 1000V (MAX: 1150V)
Ranges 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V
Accuracy 0.012%RD + 0.008%RG
Output Current 200
10
U≤10 V: ≤ 10 mA
One-channel DC Current Output
Range 0 to 300A (MAX: 300A)
Ranges 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A, 100A, 300A
Accuracy 0.012%RD + 0.008%RG
Load Capacity Port voltage ≥ 2.5V
Six-channel Indirect Current Output
Range 0 to 5V
Ranges 1mV, 3mV, 10mV, 30mV, 100mV, 300mV,
1V, 3V, 5V
Accuracy Uo ≤ 20mV: 120ppm*RD + 80ppm*RG (or 2uV) 20 mV ≤ Uo ≤ 5 V: 120ppm*RD + 80ppm*RG
Load Capacity Output 1mA for Uo ≤ 100mV
Output 10mA for 100mV < Uo ≤ 5V
Energy Accuracy
Energy Accuracy 0.05%
Voltage and Current Output Stability
Voltage Stability ±(0.01%*RD + 0.005%RG)/min
Current Stability ±(0.01%*RD + 0.005%RG or 2uV)/min
Annual Drift Less than 100ppm/year
Voltage and current ripple output capability
Ripple frequency 20~500Hz
Voltage ripple factor Allow output ripple less than 20%
Current ripple factor Allow output ripple less than 30%
Ripple phase Voltage and current ripple phase error less than 0.1 degrees
Ripple accuracy Ripple voltage accuracy: 20-50Hz: <1%
50-500Hz: <5%
Ripple small signal accuracy: 20-500Hz: <1%
Other indicators
Operating power supply AC 220V±5% 50Hz
Relative humidity ≤75% No corrosive gases
Dimensions Main unit 1592mm×1476mm×770mm (W×H×D)
Computer desk 850mm×772mm×770mm (W×H×D)

Product Document

File Name

Update Time

Related Products

XL-9100T6 DC Meter Calibration Device


The XL-9100T6 DC energy meter calibration bench includes a standard source cabinet and an energy meter hanging table body. The cabinet houses the voltage source, small signal source, current source, main control unit, and industrial control computer display unit.

XL-9201 DC Shunt Calibrator


The XL-9201T3 DC shunt calibrator can test shunts of various specifications, featuring functions such as testing the basic error and DC resistance of shunts, plotting I-R and R-t curves, and automatically calculating the power factor. Its measurement accuracy is 0.05 level. This device is equipped with a high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate shunts of various specifications, providing high testing efficiency.

XL-9600T6 DC Meter Calibration Device


The XL-9600T6 DC meter calibration device includes a standard source cabinet and an electricity meter hanging table body. The cabinet houses a voltage source, a small signal source, a current source, a main control unit, and an industrial control computer display unit. It can output DC voltage from 0 to 1000V (MAX: 1150V), DC current from 0 to 600A, and small signals from 0 to 5V, enabling incremental output for electricity meter calibration. The voltage accuracy is 0.02 level, current accuracy is 0.02 level, and energy accuracy is 0.05 level. The hanging table body is mainly used for meter position fixing, including a meter rack and table body, with six meter positions, capable of simultaneously calibrating 6 electricity meters (0~100A) and 3 electricity meters (0~600A).

XL-9201T6 DC Shunt Calibrator


The XL-9201T6 DC shunt calibrator can test various specifications of shunts according to the JJG1069-2011 DC shunt calibration regulations. It is capable of testing the basic error and DC resistance of shunts, plotting I-R curves and R-t curves, among other functions. Its measurement accuracy level is 0.05. This device is equipped with a built-in high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate various specifications of shunts, providing high testing efficiency.

XL-9100T18 DC Meter Calibration Device


The XL-9100T18 DC energy meter calibration device is equipped with 18 independent voltage sources and 1 current source. It can output DC voltage from 0 to 1500V (MAX: 1725V) and DC current from 0 to 100A, enabling incremental output calibration for direct DC energy meters. The voltage accuracy is 0.02 level, current accuracy is 0.03 level, and energy accuracy is 0.05 level. It features a dedicated meter rack with 18 slots, allowing simultaneous calibration of 18 direct energy meters (0~100A).

XL-9000T8 DC Meter Calibration Device


The XL-9000T8 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output DC voltage from 0 to 1000V (MAX: 1150V) and a small signal of 0 to 5V, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 8 slots, allowing simultaneous calibration of 8 energy meters.

XL-9000T16 DC Meter Calibration Device


The XL-9000T16 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output 0 to 1000V (MAX: 1150V) DC voltage and 0 to 5V small signals, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 16 slots, allowing simultaneous calibration of 16 energy meters.

Product Inquiry

Our staff will contact you within 24 hours (working days)