XL-9100T6 DC Meter Calibration Device

The XL-9100T6 DC energy meter calibration bench includes a standard source cabinet and an energy meter hanging table body. The cabinet houses the voltage source, small signal source, current source, main control unit, and industrial control computer display unit.

Product Description

XL-9100T6 DC Meter Calibration Device Includes a standard source cabinet and an energy meter hanging table body. The cabinet houses voltage source, small signal source, current source, main control unit, and industrial control computer display unit. It can output 0~1000V DC voltage, 0~100A DC current, 0~5V small signal, achieving incremental output for energy meter calibration. Voltage accuracy is 0.02 level, current accuracy is 0.05 level, and energy accuracy is 0.1 level; the hanging table body is mainly used for meter position fixing, including meter racks and table body, with six meter positions, capable of simultaneous calibration of 6 energy meters.

Main Functions

  • The shell is made of special aluminum alloy material, beautiful and elegant, structurally strong, lightweight, and easy to transport.
  • Uses a dedicated junction box for convenient meter calibration.
  • High-quality linear power amplifier with low ripple output and good stability.
  • Multiple protection systems with audible and visual alarm functions for higher reliability.
  • The device has an independent PC and common calibration point shortcut keys, enabling quick setting of commonly used test parameters during manual meter calibration, making manual calibration more convenient.
  • Equipped with 485 communication port function, facilitating easy reading and modification of data inside multifunction meters, capable of reading or automatically setting communication addresses for each meter position. (Optional)
  • The device has comprehensive testing functions with a dedicated wiring clamp; once the output ports of the meter under test are connected, it can automatically complete tests such as active energy and daily timing error.
  • Fully automatic inspection of energy meter start-up, creep, and basic errors according to regulations.
  • Direct large current output (0~100A), indirect current (0~5V), fully designed according to DC energy meter specifications, compatible with calibration or performance testing of various DC meters.
  • Voltage and current can each superimpose 20~500Hz ripple, with adjustable ripple amplitude and phase maintained in phase.
  • Can calibrate energy meters with different constants and has constant verification function.
  • Dedicated photoelectric sampler can collect LED light pulse signals from electronic meters.
  • Dedicated pulse sampling interface with high-voltage isolation circuit to prevent high-voltage misconnection.
  • Can perform dial test according to energy, time, or pulse count.
  • Has power-based meter calibration function, can directly read power measurement values of the meter under test via 485 bus interface and calculate errors.
  • Can display parameters such as power, voltage, current, and ripple.
  • Supports PC connection with dedicated calibration software featuring a user-friendly interface and simple calibration settings; allows manual addition and setting of any calibration points, with data storage and printing capabilities.
  • Has automatic detection of communication protocols, compliant with all agreements of DL/T 645-2007, and can modify communication agreements according to user requirements. (Optional)
  • Supports barcode input for convenient meter information entry. (Requires barcode scanner)
  • Equipped with clock reference, supports daily timing error testing of energy meters.
  • Supports self-heating test, can perform self-heating influence test on the meter under test and provide error variation curves. (Optional)
  • The device uses single-phase power supply for user convenience.
  • The polarity connection of DC meter current positive and negative can be program-controlled switched, facilitating indirect meter access; through program control, the corresponding shunt and voltage short-circuit wires can be directly shorted to prevent damage to the energy meter.
  • Each meter position has automatic and manual switching capabilities, allowing users to select meter positions participating in calibration; users can easily switch positions via software selection.
  • Supports barcode information scanning input for the meter under test; scanned information is automatically associated with the meter.
  • Equipped with 220VAC, 12VDC, 24VDC auxiliary power interfaces, adjustable ±20%, enabling power drop test for energy meters.

 

Technical Specifications

DC Energy Meter Table Positions
DC Energy Meter Table Positions 6 meter positions
Six-channel DC voltage output
Range 0~1000V
Ranges 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 200V, 300V, 1000V
Accuracy 0.012%RD + 0.008%RG
Allowable load current 200
10
U≤10 V: ≤ 10 mA
One DC current output
Range 0~100A
Ranges 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A, 100A
Accuracy 0.012%RD + 0.008%RG
Load capacity Port voltage >= 2V
Six indirect current outputs
Range 0~5V
Ranges 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V, 5V
Accuracy Uo ≤ 20mV: 120ppm*RD + 80ppm*RG (or 2uV)
20 mV ≤ Uo ≤ 5 V: 120ppm*RD + 80ppm*RG
Load capacity Output current 1mA for U ≤ 100mV;
Output 10mA for 100mV < U ≤ 5V
Electric energy accuracy
Electric energy precision 0.05%
Voltage and current output stability
Voltage stability Better than 0.01%/min
Current stability Better than 0.01% /min
Annual drift Less than 100ppm/year
Voltage and current ripple output capability
Ripple frequency 20~500Hz
Voltage ripple factor Allow output ripple less than 20%
Current ripple factor Allow output ripple less than 30%
Ripple phase Voltage and current ripple phase error less than 0.1 degrees
Ripple accuracy Voltage ripple accuracy: 20-50Hz: <1%
50-500Hz: <5%
Small signal ripple accuracy: 20-500Hz: <1%
Other specifications
Operating power supply AC 220V±5% 50Hz
Relative humidity ≤75% No corrosive gases

Product Document

File Name

Update Time

Related Products

XL-9201 DC Shunt Calibrator


The XL-9201T3 DC shunt calibrator can test shunts of various specifications, featuring functions such as testing the basic error and DC resistance of shunts, plotting I-R and R-t curves, and automatically calculating the power factor. Its measurement accuracy is 0.05 level. This device is equipped with a high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate shunts of various specifications, providing high testing efficiency.

XL-9300T6 DC Energy Meter Calibration Device


The XL-9300T6 includes a voltage source, current source, small signal source, main control unit, and meter mounting platform. It can output 0 to 1000V DC (maximum 1150V) direct current voltage, 0 to 300A DC direct current output, and 0 to 5V DC small signal output. It is capable of calibrating both indirect and direct DC energy meters with an energy accuracy level of 0.05. The meter mounting platform is mainly used for securing meter positions, featuring 6 slots, allowing simultaneous calibration of 6 energy meters.

XL-9600T6 DC Meter Calibration Device


The XL-9600T6 DC meter calibration device includes a standard source cabinet and an electricity meter hanging table body. The cabinet houses a voltage source, a small signal source, a current source, a main control unit, and an industrial control computer display unit. It can output DC voltage from 0 to 1000V (MAX: 1150V), DC current from 0 to 600A, and small signals from 0 to 5V, enabling incremental output for electricity meter calibration. The voltage accuracy is 0.02 level, current accuracy is 0.02 level, and energy accuracy is 0.05 level. The hanging table body is mainly used for meter position fixing, including a meter rack and table body, with six meter positions, capable of simultaneously calibrating 6 electricity meters (0~100A) and 3 electricity meters (0~600A).

XL-9201T6 DC Shunt Calibrator


The XL-9201T6 DC shunt calibrator can test various specifications of shunts according to the JJG1069-2011 DC shunt calibration regulations. It is capable of testing the basic error and DC resistance of shunts, plotting I-R curves and R-t curves, among other functions. Its measurement accuracy level is 0.05. This device is equipped with a built-in high-precision, high-stability DC standard source and DC standard meter, along with auxiliary fixtures for shunt calibration. After editing the test plan and placing the shunt, starting the test will automatically complete the entire testing process and generate a test report. The fixture can be adjusted to accommodate various specifications of shunts, providing high testing efficiency.

XL-9100T18 DC Meter Calibration Device


The XL-9100T18 DC energy meter calibration device is equipped with 18 independent voltage sources and 1 current source. It can output DC voltage from 0 to 1500V (MAX: 1725V) and DC current from 0 to 100A, enabling incremental output calibration for direct DC energy meters. The voltage accuracy is 0.02 level, current accuracy is 0.03 level, and energy accuracy is 0.05 level. It features a dedicated meter rack with 18 slots, allowing simultaneous calibration of 18 direct energy meters (0~100A).

XL-9000T8 DC Meter Calibration Device


The XL-9000T8 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output DC voltage from 0 to 1000V (MAX: 1150V) and a small signal of 0 to 5V, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 8 slots, allowing simultaneous calibration of 8 energy meters.

XL-9000T16 DC Meter Calibration Device


The XL-9000T16 DC energy meter calibration device includes a voltage source, a small signal source, a main control unit, and a meter mounting platform. It can output 0 to 1000V (MAX: 1150V) DC voltage and 0 to 5V small signals, enabling the calibration of indirect DC energy meters. The voltage accuracy is 0.02 level, and the energy accuracy is 0.05 level. The meter mounting platform is mainly used for fixing meter positions, featuring 16 slots, allowing simultaneous calibration of 16 energy meters.