XL-942Z Adapter Type Non-Vehicle Onboard Charger Calibration Device
The XL-942Z adapter-type non-vehicle-mounted charger calibration device, used with electric vehicles, can achieve real-time monitoring of voltage, current, power, and energy during the electric vehicle charging process.
Product Description
Scope of Application
The XL-942Z adapter-type non-vehicle-mounted charger calibration device is mainly used for inspection item testing in metrological verification. It can measure parameters such as the charger's output voltage, current, power, and energy error, and supports automated testing. The adapter gun head is simple in form and easy to operate.
Functional Features
The XL-942Z adapter-type non-vehicle-mounted charger calibration device, when used with electric vehicles, can achieve real-time monitoring of voltage, current, power, and energy during the electric vehicle charging process.
It has the following features:
- The calibration device has a built-in battery, allowing outdoor use without power access; the battery can continuously operate normally for more than 4 hours.
- Meets the voltage and current ranges of non-vehicle-mounted chargers on the market.
- Equipped with temperature and humidity sensors to monitor environmental changes on site.
- Built-in display screen to monitor data changes in real time.
- WIFI interface enables remote control and other functions.
- Built-in 4G module allows remote data upload. (Customizable)
The XL-942Z adapter-type non-vehicle-mounted charger calibration device is compact and lightweight, easy to carry, simple to operate, and provides accurate measurements. It is plug-and-play, capable of real-time detection of charger output voltage and current, with data saved at any time. It can calculate energy errors and meets the pulse and energy method verification requirements for metrological verification.
Technical Parameters
1. Voltage Measurement | |
Resolution | 0.01% RG |
Accuracy | 0.05% RD (100V–1000V) |
Input Range | 0–1150V |
2. Current Measurement | |
Resolution | 0.01% RG |
Accuracy | 0.05% RD (5A–250A) |
Input Range | 0–300A |
3. Energy Measurement | |
Energy Measurement Accuracy | 0.05% RD (100V–1000V) / (5A–250A) |
4. Temperature and Humidity Measurement | |
Temperature Measurement Range | -25°C to 55°C |
Temperature Measurement Accuracy | ±1°C |
Temperature Measurement Resolution | 0.1°C |
Humidity Measurement Range | 0%RH to 99.9%RH |
Humidity Measurement Accuracy | ±10%RH |
Humidity Measurement Resolution | 0.1%RH |
5. Other Specifications | |
Power Supply | Built-in battery, can work continuously for 3 hours |
Power Consumption | ≤6W |
Operating Temperature | -20°C to 50°C |
Relative Humidity | ≤90% |
Storage Conditions | -20°C to 50°C |
Warm-up Time | 2 minutes |
Embedded Calibration Instrument Size | 85mm*55mm (Length*Width) |
Overall Dimensions | 350mm*160mm*220mm (Length*Width*Height) |
Overall Weight | 4.2kg |
Product Document
File Name
Update Time
Related Products
XL-943S AC Charging Pile On-site Characteristic Tester
XL-942S Non-Vehicle On-Site Charger Characteristic Tester
XL-943Z Adapter Type AC Charging Pile Calibration Device
XL-A3431 Single-phase AC Programmable Load
XL-A3433 Three-Phase AC Programmable Load (including XL-A3433L)
XL-A3603 DC Programmable Load (including XL-A3603P, XL-A3606C, XL-A3606P)
XL-943L AC Charging Pile Characteristic Test Device (Single Phase)
XL-942L Non-Vehicle Onboard Charger Characteristic Testing Device
XL-942ES European Standard DC Charging Pile On-site Characteristic Tester
XL-942SC Super Charging Pile On-site Characteristic Tester
XL-943P Integrated AC Charging Pile Calibration Device
XL-942P Integrated Non-Vehicle Onboard Charger Calibration Device
Product Inquiry