XL-943P Integrated AC Charging Pile Calibration Device
The XL-943P integrated AC charging pile calibration device can perform metrological verification and operational error checking of AC charging piles.
Product Description
Product Introduction
XL-943P Integrated AC Charging Pile Verification Device It can realize the metrological verification, operation and maintenance error check, start-stop tests of AC charging piles. It can simultaneously measure the output voltage, current, power, electric energy, harmonics, phase, frequency, waveform distortion rate, and clock error of the charging pile. It also features insulation resistance testing, temperature acquisition, humidity acquisition, GPS Beijing time calibration, and supports fully automated testing. The large screen Chinese menu display shows a large amount of information and is easy to operate.
Verification Items
Table 1. "JJG 1148-2022 Verification Regulations for Electric Vehicle AC Charging Piles" |
|||
Serial Number | Test Item | Corresponding Chapter | Remarks |
1 | Appearance and Function Check | 7.3.2.1 | |
2 | Operating Error | 7.3.2.2 | |
3 | Clock Time Error | 7.3.2.3 |
Technical Parameters
1. Voltage Measurement | |
Input Range | 0~264V |
Accuracy | ±0.05%RD (110V~264V) |
Resolution | 0.01%RG |
2. Current Measurement | |
Input Range | 0~72V |
Accuracy | ±0.05%RD (0.1A~72A) |
Resolution | 0.01%RG |
3. Electric Energy Measurement | |
Electric Energy Measurement Accuracy | ±0.05%RD (110V~264V) / (0.1A~72A) |
4. Insulation Resistance Measurement | |
Voltage Range | 500V, 1000V |
Resistance Measurement Range | 1MΩ~50MΩ |
Resistance Measurement Accuracy | ±5%RD |
5. Clock Measurement | |
Time Synchronization Method | Built-in GPS Time Synchronization |
Measurement Accuracy | ±1s |
6. Harmonic Measurement | |
Measurement Range | 2~127th order |
Accuracy | ±1%RG (2~22th order) |
7. Phase Measurement | |
Measurement Range | 0~359.99° |
Resolution | 0.01° |
Accuracy | ±0.05° |
8. Frequency Measurement | |
Measurement Range | 45Hz~65Hz |
Resolution | 0.001Hz |
Accuracy | ±0.005Hz |
9. Temperature and Humidity Measurement | |
Temperature Measurement Range | -25℃~55℃ |
Temperature Measurement Accuracy | ±1°C |
Temperature Measurement Resolution | 0.1°C |
Humidity Measurement Range | 0%RH~99%RH |
Humidity Measurement Accuracy | ±10%RH |
Humidity Measurement Resolution | 0.1%RH |
10. Load | |
Load | 8kW |
Minimum Step | 0.01kW@200V |
Number of Gears | 8192 |
11. Other Indicators | |
Power Supply | 220V (±5%) AC @50Hz or battery or charging pile |
Power Consumption | 75W |
Operating Temperature | -20℃~60℃ |
Relative Humidity | ≤85% |
Storage Conditions | -30℃~60℃ |
Warm-up Time | 5 minutes |
Dimensions (L×W×H) | 365mm*215.5mm*531mm (L*W*H) |
Total Weight | 18kg |
Product Document
File Name
Update Time
Related Products
XL-943S AC Charging Pile On-site Characteristic Tester
XL-942S Non-Vehicle On-Site Charger Characteristic Tester
XL-943Z Adapter Type AC Charging Pile Calibration Device
XL-A3431 Single-phase AC Programmable Load
XL-A3433 Three-Phase AC Programmable Load (including XL-A3433L)
XL-A3603 DC Programmable Load (including XL-A3603P, XL-A3606C, XL-A3606P)
XL-942Z Adapter Type Non-Vehicle Onboard Charger Calibration Device
XL-943L AC Charging Pile Characteristic Test Device (Single Phase)
XL-942L Non-Vehicle Onboard Charger Characteristic Testing Device
XL-942ES European Standard DC Charging Pile On-site Characteristic Tester
XL-942SC Super Charging Pile On-site Characteristic Tester
XL-942P Integrated Non-Vehicle Onboard Charger Calibration Device
Product Inquiry