XL-A923F AC Charging Pile Factory Testing Platform
The XL-A923F AC charging pile national and European standard factory inspection platform mainly consists of an AC charging pile comprehensive testing device and an AC charging pile detection system interface cabinet, meeting the testing requirements for metrological verification and interoperability testing. During the interoperability testing process, waveforms and messages are displayed graphically in real-time, making the working status clear at a glance. The equipment connects to the router via a network cable, allowing data to be transmitted wirelessly and enabling remote control through wireless devices such as tablet computers.
Product Description
Features
- Built-in waveform recording module with 8-channel recording capability, supporting global waveform and event waveform, automatically capturing fault moments;
- Equipped with database functionality, test records are automatically generated and can be queried and exported by number, date, and other methods;
- Project editing function available, selectable verification projects, automatic process detection, automatic calculation of minimum time and minimum energy required for verification, saving customers time, money, and effort;
- Built-in insulation resistance testing module, integrated design, no complicated wiring required, safe and efficient;
- Vehicle interface simulator function, used with load box to verify working error and display value error.
Test items (can complete the following standard tests)
- "JJG 1148-2022 Verification Regulations for Electric Vehicle AC Charging Piles"
- "GB/T 34657.1-2017" Conductive Charging Interoperability Test Items
- "NB/T 33008.2 Electric Vehicle Charging Equipment Inspection and Test Specification Part 2: AC Charging Piles"
- "IEC61851-1 Electric vehicle conductive charging system. General requirements"
Technical Specifications
1. AC Voltage Measurement | |
Resolution | 0.01% RG |
Accuracy | ±0.05% RD (50%~120%) |
Rated Input | 220V (phase voltage) / 380V (line voltage) |
Input Range | 0%~120% |
2. AC Current Measurement | |
Resolution | 0.01% RG |
Accuracy | ±0.05% RD (1%~110%) |
Rated Input | 63A (phase current) |
Input Range | 0%~110% |
3. AC Energy Measurement | |
Energy Measurement Accuracy | ±0.05% RD @ (50%~120% Un) / (1%~110 In) |
4. Insulation Resistance Measurement | |
Voltage Range | 500V, 1000V |
Resistance Measurement Range | 5MΩ~50MΩ |
5. Clock Measurement | |
Measurement Accuracy | ≤1s (built-in GPS) |
6. Harmonic Measurement | |
Measurement Range | 2~127 orders |
Accuracy | ±1% RG (2~22 orders) |
7. Phase Measurement | |
Measurement Range | 0~359.99° |
Resolution | 0.01° |
Accuracy | ±0.05° |
8. Frequency Measurement | |
Measurement Range | 45Hz~65Hz |
Resolution | 0.001Hz |
Accuracy | ±0.005Hz |
9. Temperature and Humidity Measurement | |
Temperature Measurement Range | -25℃~55℃ |
Temperature Measurement Accuracy | ±1°C |
Temperature Measurement Resolution | 0.1°C |
Humidity Measurement Range | 0%RH~99%RH |
Humidity Measurement Accuracy | ±10%RH |
Humidity Measurement Resolution | 1%RH |
10. Overall Machine Specifications | |
Operating Power Supply | 220V (±5%) AC @50Hz |
Maximum Power Consumption | <1000VA |
Operating Temperature | -20℃~60℃ |
Relative Humidity | ≤85% |
Storage Conditions | -30℃~60℃ |
Warm-up Time | 5 minutes |
Product Document
File Name
Update Time
Related Products
XL-A922C Super Charging Pile Comprehensive Testing System
XL-A922F Non-Vehicle Onboard Charger Factory Testing Platform
XL-A923S Series Comprehensive Test System for AC Charging Piles in China, Europe, and America
XL-A392D DC Short Circuit Test Device
XL-A392A AC Short Circuit Test Device
XL-A672 DC Charging Pile Connector Overtemperature Simulator
XL-A501C Supercharge Charging Simulator
XL-A3436 Three-Phase AC Programmable Load
Product Inquiry